Skip to main content
Siemens 3RH2140-1AP00-ZW96 — Contactors

Siemens 3RH2140-1AP00-ZW96 SIRIUS Auxiliary Contactor, 4 N/O

MPN3RH2140-1AP00-ZW96
Active

Siemens SIRIUS auxiliary contactor, size S00, 4 N/O instantaneous contacts, screw and snap-on mounting on 35 mm DIN rail, 3RH2140-1AP00-ZW96.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RH2140-1AP00-ZW96 — Identification
ParameterValue
Contactor frame sizeS00
3RH2140-1AP00-ZW96 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V10 A
Rated value @ 24 V10 A
Rated value @ 60 V4.7 A
Rated value @ 110 V3 A
Rated value @ 220 V1.2 A
3RH2140-1AP00-ZW96 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RH2140-1AP00-ZW96 — Contacts & Poles
ParameterValue
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RH2140-1AP00-ZW96 — Connection & Mounting
ParameterValue
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail
3RH2140-1AP00-ZW96 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RH2140-1AP00-ZW96 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RH2140-1AP00-ZW96 — Mechanical
ParameterValue
Width45 mm
Height57.5 mm
Depth73 mm
3RH2140-1AP00-ZW96 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

The Siemens 3RH2140-1AP00-ZW96 is a SIRIUS auxiliary contactor, size S00, with four normally-open instantaneous contacts. It's designed for signal switching and control logic extension in motor starter and contactor assemblies, not for direct motor loads.

At 24 V DC the same contacts carry 10 A, dropping to 1.2 A at 220 V DC and 0.26 A at 600 V DC — so for DC switching at higher voltages, derate significantly. Mechanical life is listed at 30,000,000 operating cycles typical, which is high for a control relay — this part is built for frequent switching in automated lines, not occasional manual override.

The screw terminals accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm² solid or stranded wire — typical for control wiring up to 4 mm².

Frequently asked questions

What are the key dimensions of this auxiliary contactor?

Width is 45 mm, height is 57.5 mm, and depth is 73 mm. It mounts on a 35 mm DIN rail.

What is the contact configuration and rated current?

It has 4 normally-open instantaneous contacts. At 230 V AC the rated current is 10 A; at 24 V DC it is also 10 A, derating to 0.26 A at 600 V DC.

What compliance documentation is available?

The part carries a substance prohibition date of 10/01/2009, indicating RoHS compliance. It is a Siemens SIRIUS product with standard CE/UL/CSA certifications typical for the series.

MPN
3RH2140-1AP00-ZW96