Skip to main content
Siemens 3RT2015-1AK61-1AA0 — Contactors

Siemens SIRIUS 3RT2015-1AK61-1AA0 Power Contactor, Size S00,

MPN3RT2015-1AK61-1AA0
Active

Siemens SIRIUS power contactor, Size S00, 3RT2015-1AK61-1AA0, 45 mm width, screw-type coil terminals, auxiliary switch included, screw and snap-on 35 mm DIN rail mounting.

$17.78Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3RT2015-1AK61-1AA0 — Identification
ParameterValue
Contactor frame sizeS00
3RT2015-1AK61-1AA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V6.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V0.75 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2015-1AK61-1AA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.24
Rated value @ 50 Hz110 V
3RT2015-1AK61-1AA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2015-1AK61-1AA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 35A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2015-1AK61-1AA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), 2x 4 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2015-1AK61-1AA0 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2015-1AK61-1AA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2015-1AK61-1AA0 — Mechanical
ParameterValue
Width45 mm
Height58 mm
Depth73 mm
3RT2015-1AK61-1AA0 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

What Fits — Panel & Wiring

The 3RT2015-1AK61-1AA0: Size S00 frame, 45 mm wide, 58 mm tall, 73 mm deep. That depth is the body only — you still need clearance for the coil terminals (screw-type) and any auxiliary block you add on top. That's tight enough for a crowded panel, but don't stack it flush against a bigger contactor or the arc-chamber venting gets compromised. Wire range: solid or stranded 0.5 to 4 mm². For two conductors in one clamp, it accepts 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm². That covers most control-circuit and small-power wiring in a standard panel — no need for pin terminals if you're terminating ferruled stranded, but the spring-force is designed for the listed cross-sections.

Auxiliary Contact & Switching Duty

The contactor ships with an auxiliary switch built in. That's one less block to order separately. The auxiliary contact ratings are given per voltage: 10 A at 24 V, 2 A at 48 V and 60 V, 1 A at 110 V, 0.9 A at 125 V, 0.3 A at 220 V, 3 A at 400 V, and 0.14 A at 440 V. These are resistive-load figures — if you're switching an inductive PLC input or a small relay coil, derate by at least 30% or add a flyback diode.

Environmental & Mounting

The storage figure governs handling during shipping and warehouse idle — the contactor won't degrade in a cold truck, but you can't run it at -55 °C. Mounting position is standing on a horizontal surface; any other orientation reduces the rated current and requires derating.

Frequently asked questions

What is the depth of this contactor?

73 mm body depth. Add clearance for coil terminals and any auxiliary contact block mounted on top — the 73 mm is the enclosure envelope, not the installed projection.

What wire sizes does it accept?

Solid or stranded 0.5 to 4 mm². For two wires in one clamp: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or 2x 4 mm².

MPN