Skip to main content
Siemens 3RT2017-2AB01-ZW96 — Contactors

Siemens SIRIUS 3RT2017-2AB01-ZW96 Power Contactor, Size S00,

MPN3RT2017-2AB01-ZW96
Active

Siemens SIRIUS power contactor, 3RT2017-2AB01-ZW96, size S00, 45 mm width, spring-type coil terminals, screw and snap-on mounting on 35 mm DIN rail.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT2017-2AB01-ZW96 — Identification
ParameterValue
Contactor frame sizeS00
3RT2017-2AB01-ZW96 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V8.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V2 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2017-2AB01-ZW96 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz24 V
3RT2017-2AB01-ZW96 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2017-2AB01-ZW96 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 50A (690V,100kA), aM: 20A (690V,100kA), BS88: 35A (415V,80kA)
Short-circuit coordination type 2, fusegG: 20A (690V,100kA), aM: 16A (690V, 100kA), BS88: 20A (415V, 80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2017-2AB01-ZW96 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 60715
Side-by-side mountingYes
3RT2017-2AB01-ZW96 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2017-2AB01-ZW96 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2017-2AB01-ZW96 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm
3RT2017-2AB01-ZW96 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

Its 45 mm width and 73 mm depth fit standard DIN-rail enclosures with screw and snap-on mounting per DIN EN 60715. The contactor carries an auxiliary switch and spring-type terminals on the coil, accepting solid or stranded conductors from 0.5 to 4 mm². Mechanical service life is rated at 30,000,000 operations typical.

Switching Performance and Duty Ratings

Maximum switching frequency varies by duty class: 1,000 cycles/hour at AC-1 (resistive), 750 cycles/hour at AC-2 and AC-3 (motor start/run), and 250 cycles/hour at AC-4 (plugging/inching). The AC-3e rating also caps at 750 cycles/hour, matching standard motor switching. Arcing time spans 10 to 15 ms at AC, and the main contacts are rated for 20 to 12 — the range covering typical motor inrush and running currents for this frame size.

Mounting and Clearance Requirements

Mounting position allows ±180° rotation on a vertical surface and ±22.5° tilt forward/backward. Required clearances: 10 mm upward, 10 mm downward, 10 mm forward, 6 mm at the side — critical for heat dissipation and arc flash containment in tight panels. Operating temperature range is -25 to +60 °C during operation, with storage from -55 to +80 °C.

Frequently asked questions

What are the key dimensions and clearances for panel integration?

The contactor measures 45 mm wide, 70 mm high, and 73 mm deep. Required clearances are 10 mm upward, downward, and forward, with 6 mm at the sides for proper ventilation and arc containment.

What conductor sizes does the spring-type coil terminal accept?

The spring-type terminals accept solid or stranded conductors from 0.5 to 4 mm², including 2x (0.5 to 4 mm²) for parallel runs.

What switching frequencies can this contactor handle?

Maximum switching frequency depends on duty: 1,000 cycles/hour at AC-1, 750 cycles/hour at AC-2, AC-3, and AC-3e, and 250 cycles/hour at AC-4 for heavy inching/plugging duty.

MPN
3RT2017-2AB01-ZW96