Siemens 3RT2018-2AB01-ZW96 — Contactors

Siemens 3RT2018-2AB01-ZW96 SIRIUS S00 Power Contactor, 10 A

MPN3RT2018-2AB01-ZW96
Active

Siemens SIRIUS S00 power contactor, 3RT2018-2AB01-ZW96, 10 A at 24 V rated value, spring-type terminals, screw and snap-on mounting onto 35 mm DIN rail, 73 mm depth, 45 mm width, 70 mm height.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT2018-2AB01-ZW96 — Identification
ParameterValue
Contactor frame sizeS00
3RT2018-2AB01-ZW96 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V11.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V2 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2018-2AB01-ZW96 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz24 V
3RT2018-2AB01-ZW96 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2018-2AB01-ZW96 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 50A (690V,100kA), aM: 25A (690V,100kA), BS88: 50A (415V,80kA)
Short-circuit coordination type 2, fusegG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2018-2AB01-ZW96 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid0.5 ... 4 mm²
Conductor cross-section, solid or stranded2x (0,5 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2018-2AB01-ZW96 — Durability
ParameterValue
Durability (operating cycles, typ.)30 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2018-2AB01-ZW96 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2018-2AB01-ZW96 — Mechanical
ParameterValue
Width45 mm
Height70 mm
Depth73 mm
3RT2018-2AB01-ZW96 — Specifications
ParameterValue
At AC4 ... 15 ms

Product details

The 3RT2018-2AB01-ZW96: The S00 frame occupies 45 mm width, 70 mm height, and 73 mm depth — a compact footprint that leaves room for adjacent devices in a crowded enclosure.

Auxiliary contact ratings — matching the control voltage

These are the switching capacities the buyer must match to the PLC output or relay driving the coil — oversizing the contactor does not increase the auxiliary rating. The coil connection uses spring-type terminals, which hold the wire under vibration better than screw clamps and reduce wiring time on the panel assembly line.

Switching frequency limits per duty class

The AC-3e rating also caps at 750 ops/h. These limits govern the application: a conveyor running continuous cycles stays within AC-3, while a crane hoist with frequent reversals must respect the AC-4 ceiling. The arcing time spans 4–15 ms at AC and 10–15 ms overall, a window that determines minimum clearance to adjacent components for arc quenching.

Panel fit and thermal clearance

These air gaps are needed for heat dissipation and arc quenching — crowding the contactor against other devices or the enclosure wall reduces the switching frequency ceiling and accelerates contact wear. Main contacts accept 20–12 AWG. The spring-type terminals on the coil side eliminate the need for screw tightening, reducing wiring time and the risk of loose connections under thermal cycling.