Siemens 3RT2025-2AK60 — Contactors

Siemens 3RT2025-2AK60 SIRIUS Power Contactor, S0 Frame, 24 V

MPN3RT2025-2AK60
Active

Siemens SIRIUS power contactor, 3RT2025-2AK60, S0 frame, 24 VDC coil, spring-type terminals, 10 A at 24 V rated value, 3 hp at 230 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3RT2025-2AK60 — Identification
ParameterValue
Contactor frame sizeS0
3RT2025-2AK60 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V15.5 A
Rated value @ 400 V3 A
Rated value @ 500 V2 A
Rated value @ 690 V1 A
Rated value @ 230 V3 hp
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT2025-2AK60 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.25
Rated value @ 50 Hz110 V
3RT2025-2AK60 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT2025-2AK60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusegG: 63A (690V,100kA), aM: 32A (690V,100kA), BS88: 63A (415V,80kA)
Short-circuit coordination type 2, fusegG: 25A (690V,100kA), aM: 20A (690V,100kA), BS88: 25A (415V,80kA)
Aux. switch short-circuit protection, fusegG: 10 A (500 V, 1 kA)
3RT2025-2AK60 — Connection & Mounting
ParameterValue
Main circuit connectionspring-loaded terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid1 ... 10 mm²
Conductor cross-section, solid or stranded2x (0.5 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm DIN rail according to DIN EN 60715
Side-by-side mountingYes
3RT2025-2AK60 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT2025-2AK60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT2025-2AK60 — Mechanical
ParameterValue
Width45 mm
Height102 mm
Depth97 mm
3RT2025-2AK60 — Specifications
ParameterValue
At AC4 ... 16 ms

Product details

It lands as a current-production part (lifecycle stage: current), so it's still a standard BOM line, not a scavenger hunt. The 24 VDC coil pulls in at nominal voltage and drops out reliably below the minimum hold threshold — standard for PLC-driven panels where the DC supply is shared across I/O and contactors. Main contact ratings: 10 A at 24 V rated value, 3 hp at 230 V, and 3 A at 400 V — so it'll handle small motors, fans, pumps, and resistive heaters inside a 480 V panel. The auxiliary switch (1 N/O + 1 N/C, 18...8 configuration) gives you feedback for the PLC or a seal-in circuit without bolting on a separate aux block.

The S0 frame is 45 mm wide, 102 mm tall, 97 mm deep — fits the standard panel layout without surprises. That's tight enough for a dense row of contactors on the rail, but leave the side gap for heat rise if you're running near the AC-3 switching limit of 1,000 cycles per hour.

Duty and Environment

Rated for 1,000 operating cycles per hour under AC-1, AC-2, AC-3, and AC-3e duty; drops to 300 cycles per hour under AC-4 (plugging/reversing). Storage temperature spans -55 to +80 °C, which matters if the spare sits in a non-climate-controlled warehouse for a couple years. The arcing time is 10 ms, and the switching times at AC are 4 to 16 ms — fast enough for most sequencing but not a high-speed transfer switch.

Frequently asked questions

How do I get current pricing and availability for 3RT2025-2AK60?

Submit an RFQ through this listing. Pricing and stock levels are confirmed at quote time based on current market conditions and our sourcing reach.

What is 3RT2025-2AK60's listed depth?

The depth is 97 mm, with a width of 45 mm and height of 102 mm for the S0 frame.

What wire sizes does the 3RT2025-2AK60 accept on the spring terminals?

The spring-type terminals accept solid or stranded wire from 1 to 10 mm², and 2x (0.5 to 2.5 mm²) for the auxiliary contacts.

Will 3RT2025-2AK60 drop into a panel specified around 3RT2016-1AG62 without rewiring?

Both are S0 frame contactors with the same mounting footprint on 35 mm DIN rail, so the mechanical swap is straightforward. However, verify the coil voltage and current ratings — 3RT2025-2AK60 has a 24 VDC coil and a 10 A rating at 24 V, while the 3RT2016-1AG62 may differ. Check your BOM against the nameplate before committing.