Siemens 3VA1032-2ED46-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1032-2ED46-0AA0 SENTRON MCCB, 32 A, 4-Pole, 52.5

MPN3VA1032-2ED46-0AA0
Active

Siemens SENTRON 3VA1032-2ED46-0AA0, 4-pole molded case circuit breaker, 32 A, 52.5 kA at 240 V, TM210 release, line protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA1032-2ED46-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA1032-2ED46-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C32 A
Current at 45 °C32 A
Current at 50 °C32 A
Current at 55 °C31 A
Current at 60 °C31 A
Current at 65 °C30 A
Current at 70 °C30 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.10.6 W
3VA1032-2ED46-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1032-2ED46-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal on both sides
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1032-2ED46-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA1032-2ED46-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1032-2ED46-0AA0 — Mechanical
ParameterValue
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

What this 4-pole MCCB delivers

The Siemens 3VA1032-2ED46-0AA0 is a SENTRON 4-pole molded case circuit breaker rated 32 A continuous at 40 °C, with a TM210 thermal-magnetic release for line protection. Its interrupting capacity hits 52.5 kA at 240 V and 32 kA at 415 V, so it clears high-fault currents in a 4-wire distribution panel without cascading upstream. The 70 mm depth and 101.6 mm width fit standard SENTRON mounting footprints — no panel rework needed for a like-for-like swap.

The 32 A rating holds flat from 40 °C to 50 °C, then derates to 31 A at 55 °C and 30 A at 70 °C — useful for a warm enclosure without oversizing. At 690 V the interrupting capacity is still 7.5 kA, enough for most industrial line-side faults. The TM210 release gives a fixed thermal pickup and magnetic trip, so no field adjustment — set it and forget it.

Four poles handle three-phase plus neutral switching — no separate N-conductor protection module needed. Power loss is 10.6 W maximum, so ventilation in a sealed cabinet is advisable if multiple breakers are ganged.

Frequently asked questions

What is the interrupting capacity of 3VA1032-2ED46-0AA0 at 415 V?

32 kA at 415 V. At 240 V it is 52.5 kA, and at 690 V it is 7.5 kA.

Where can I buy 3VA1032-2ED46-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — no stock count or price is listed here.

Will 3VA1032-2ED46-0AA0 drop into a panel specified around 3VA1020-3ED36-0AA0?

Both are SENTRON 3VA frame breakers with the same 70 mm depth and 101.6 mm width, so the physical footprint is identical. The key difference is the rating: this one is 32 A, 4-pole with a TM210 release; the peer is a lower-current variant. No rewiring is needed if the bus and load match the 32 A rating.

MPN