Siemens 3VA1080-2ED42-0AC0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1080-2ED42-0AC0 SENTRON MCCB, 80 A, 4-Pole

MPN3VA1080-2ED42-0AC0

Siemens SENTRON 3VA1080-2ED42-0AC0, molded case circuit breaker, 4-pole, 80 A rated at 40 °C, TM210 thermal-magnetic release, line protection design.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1080-2ED42-0AC0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA10802ED420AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1080-2ED42-0AC0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C80 A
Current at 45 °C80 A
Current at 50 °C80 A
Current at 55 °C78 A
Current at 60 °C77 A
Current at 65 °C75 A
Current at 70 °C74 A
Switching capacity classB
Breaking capacity at 240 V52.5 kA
Breaking capacity at 415 V32 kA
Breaking capacity at 440 V13.6 kA
Breaking capacity at 500 V7.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.19.2 W
3VA1080-2ED42-0AC0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1080-2ED42-0AC0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1080-2ED42-0AC0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts2
3VA1080-2ED42-0AC0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1080-2ED42-0AC0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width101.6 mm
Depth70 mm
Height (in)5.12 in
Width (in)4 in
Depth (in)2.76 in

Product details

Siemens SENTRON 3VA1080-2ED42-0AC0 — 80 A MCCB, Line Protection

It carries an 80 A continuous current at 40 °C (derated to 74 A at 70 °C) and a TM210 thermal-magnetic overcurrent release — the '210' designates a fixed thermal pickup with magnetic adjustment range typical of this series. The 4-pole configuration covers three-phase plus neutral, making it a fit for main or feeder protection in distribution panels where full isolation of all live conductors is required. Breaking capacity is voltage-dependent: 52.5 kA at 240 V, 32 kA at 415 V, 13.6 kA at 440 V, and 7.5 kA at 500 V and 690 V. At 415 V — the common industrial three-phase level — the 32 kA SCCR provides headroom for most secondary distribution applications without requiring a current-limiting upstream device.

The 3VA1080-2ED42-0AC0 measures 70 mm deep, 101.6 mm wide, and 130 mm tall. That 101.6 mm (4-inch) width is the standard 4-pole MCCB footprint in the SENTRON 3VA platform — it occupies the same mounting cutout and busbar pitch as other 4-pole 3VA frames, so a panel laid out for a 3VA1010-2ED32-0AD0 will accept this breaker without rewiring the bus or re-drilling the mounting plate. The breaker ships with two HQ auxiliary switches fitted (design of the auxiliary switch: 2 auxiliary switches HQ). The trip indicator is not present, so visual trip status is read from the handle position or the auxiliary switch state.

Frequently asked questions

Where can I buy 3VA1080-2ED42-0AC0 and how is it quoted?

This part is sourced through independent distribution and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

Will 3VA1080-2ED42-0AC0 drop into a panel specified around 3VA1010-2ED32-0AD0?

Yes — both are 4-pole SENTRON 3VA breakers sharing the same 101.6 mm width and mounting footprint. The 3VA1080-2ED42-0AC0 carries a higher 80 A rating versus the 3VA1010-2ED32-0AD0, so verify the busbar and cable sizing can handle the increased current, but the mechanical fit is identical.

What compliance documentation does Siemens provide for 3VA1080-2ED42-0AC0?

As a standard SENTRON MCCB, this part is designed to meet IEC 60947-2 and UL 489 requirements. Siemens typically provides a Declaration of Conformity (CE/UKCA), RoHS and REACH compliance statements, and a UL file number upon request through the standard documentation portal.

What is the maximum power loss of this MCCB?

19.2 W maximum at rated current — a figure to include in panel thermal calculations when multiple breakers are ganged in a confined enclosure.

MPN
3VA1080-2ED42-0AC0