Skip to main content
Siemens 3VA1112-5ED32-0AD0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1112-5ED32-0AD0 SENTRON MCCB, 125 A, 187 kA at 24

MPN3VA1112-5ED32-0AD0

Siemens SENTRON 3VA1112-5ED32-0AD0, 3-pole molded case circuit breaker, 125 A, TM210 thermal-magnetic trip, 187 kA interrupting at 240 V, line protection design.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1112-5ED32-0AD0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA11125ED320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA1112-5ED32-0AD0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C125 A
Current at 45 °C125 A
Current at 50 °C125 A
Current at 55 °C122 A
Current at 60 °C120 A
Current at 65 °C117 A
Current at 70 °C114 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V17 kA
Breaking capacity at 690 V17 kA
Power loss, max.28.1 W
3VA1112-5ED32-0AD0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1112-5ED32-0AD0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1112-5ED32-0AD0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA1112-5ED32-0AD0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1112-5ED32-0AD0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height130 mm
Width76.2 mm
Depth70 mm
Height (in)5.12 in
Width (in)3 in
Depth (in)2.76 in

Product details

What the ratings mean for fit

The Siemens 3VA1112-5ED32-0AD0 is a SENTRON 3-pole molded case circuit breaker (MCCB) rated 125 A continuous at 40 °C, with a TM210 thermal-magnetic trip unit designed for line protection — meaning it protects cables and busbars from overload and short-circuit, not motor or generator circuits. The interrupting ratings tell the real story: 187 kA at 240 V, 121 kA at 415 V, 75.6 kA at 440 V, and 17 kA at 500 V and 690 V. That 187 kA figure at 240 V is the headline — it safely clears a fault of that magnitude without the arc flashing over or the breaker rupturing, which matters when you're coordinating downstream devices in a high-fault-current panel. At 690 V the 17 kA rating is still substantial for most industrial distribution. The insulation voltage is rated 800 V, so the breaker is physically built to withstand that voltage between phases and to ground, even though the interrupting capability drops at higher voltages.

Panel integration and mounting

The 3VA1112-5ED32-0AD0 measures 130 mm high, 76.2 mm wide, and 70 mm deep. Three-pole footprint means it occupies three module-widths on a DIN rail or panel-mount base. The 70 mm depth is shallow enough that it clears most standard enclosure gland plates without interference. Rated for -25 °C to 70 °C operating ambient, with a maximum power loss of 28.1 W at full load — that heat has to be considered in the enclosure thermal calculation, especially if several breakers are ganged. Storage range is -40 °C to 80 °C.

Trip unit and design details

The TM210 designation means a thermal-magnetic trip with a fixed thermal pickup and magnetic short-circuit response — no electronic adjustment, no communication function, no undervoltage release, and no ground-fault monitoring on this variant. It's a straight line-protection breaker: set the rating, wire it, and it clears. The auxiliary switch design is listed as 3 auxiliary switches HQ, which means it has three built-in auxiliary contacts for status feedback to a PLC or indicator lamp. The supplied basic switch order code is 3VA11125ED320AA0, confirming the internal mechanism is the same as that variant.

Frequently asked questions

What is the interrupting rating of 3VA1112-5ED32-0AD0 at 240 V?

187 kA at 240 V, which is the highest interrupting rating this breaker carries.

What is the continuous current rating of 3VA1112-5ED32-0AD0?

125 A at 40 °C, with derating to 114 A at 70 °C.

What trip unit does 3VA1112-5ED32-0AD0 use?

A TM210 thermal-magnetic trip unit, fixed setting, designed for line protection.

Where can I buy 3VA1112-5ED32-0AD0?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

MPN
3VA1112-5ED32-0AD0