Siemens 3VA1220-5EF32-0AF0 — Molded Case Circuit Breakers (MCCB)

3VA1220-5EF32-0AF0 SENTRON MCCB, 200 A, 3-pole, 187 kA at 24

MPN3VA1220-5EF32-0AF0

Siemens SENTRON 3VA1220-5EF32-0AF0, molded case circuit breaker, line protection, 3-pole, 200 A rated continuous current, 187 kA interrupting capacity at 240 V, TM240 overcurrent release, IP40 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1220-5EF32-0AF0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Integrated auxiliary / alarm switch ref.3VA9988-0AB12
3VA1220-5EF32-0AF0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V36 kA
Breaking capacity at 690 V17 kA
3VA1220-5EF32-0AF0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
3VA1220-5EF32-0AF0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1220-5EF32-0AF0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1220-5EF32-0AF0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1220-5EF32-0AF0 — Mechanical
ParameterValue
Height158 mm
Width105 mm
Depth70 mm

Product details

The Siemens SENTRON 3VA1220-5EF32-0AF0 is a 3-pole molded case circuit breaker rated for 200 A continuous current at 40 °C, with a TM240 thermal-magnetic overcurrent release. Its interrupting capacity reaches 187 kA at 240 V and 121 kA at 415 V — figures that place it in high-fault-duty distribution panels where upstream transformer capacity or parallel feeds drive available fault current above typical 65 kA MCCB ratings. The 200 A rating holds flat from 40 °C through 50 °C, then derates to 194 A at 55 °C, 188 A at 60 °C, 182 A at 65 °C, and 176 A at 70 °C. Dimensions are 105 mm wide by 158 mm high by 70 mm deep.

Interrupting capacity and selectivity planning

At 440 V the breaker clears 36 kA; at 690 V it clears 17 kA.

The 105 mm width occupies three module spaces, leaving room alongside for a disconnect or meter in a typical 24-module distribution board. Latching endurance is rated at 15,000 operations — sufficient for main breaker duty where switching cycles are infrequent. The storage minimum matters for unheated warehouses in cold climates — the breaker can be stored at -40 °C without damage, but must be at -25 °C or above before energizing.

Frequently asked questions

Where can I buy 3VA1220-5EF32-0AF0 and what is the lead time?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm lead time and price.

What is the interrupting capacity of 3VA1220-5EF32-0AF0 at different voltages?

The interrupting capacity is 187 kA at 240 V, 121 kA at 415 V, 36 kA at 440 V, and 17 kA at 690 V. These values allow coordination in high-fault-current distribution panels.

Does 3VA1220-5EF32-0AF0 include auxiliary contacts or communication?

It includes 1 auxiliary switch plus 1 trip alarm switch (HQ type). No communication module, undervoltage release, or ground-fault monitoring is fitted on this variant.

MPN
3VA1220-5EF32-0AF0