Skip to main content
Siemens 3VA1220-6EE32-0AA0 — Molded Case Circuit Breakers (MCCB)

SENTRON 3VA1220-6EE32-0AA0 MCCB, 200 A, 3-Pole, TM220 Trip

MPN3VA1220-6EE32-0AA0

SENTRON 3VA1220-6EE32-0AA0, molded case circuit breaker, 3-pole, TM220 thermal-magnetic overcurrent release, 200 A at 40 °C, interrupting rating 220 kA at 240 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA1220-6EE32-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA1220-6EE32-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C200 A
Current at 45 °C200 A
Current at 50 °C200 A
Current at 55 °C194 A
Current at 60 °C188 A
Current at 65 °C182 A
Current at 70 °C176 A
Switching capacity classH
Breaking capacity at 240 V220 kA
Breaking capacity at 415 V154 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V30 kA
Breaking capacity at 690 V17 kA
Power loss, max.42 W
3VA1220-6EE32-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM220
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA1220-6EE32-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1220-6EE32-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA1220-6EE32-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1220-6EE32-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.20 000
Height158 mm
Width105 mm
Depth70 mm
Height (in)6.22 in
Width (in)4.13 in
Depth (in)2.76 in

Product details

Its job is to clear a fault before it propagates upstream, and the interrupting ratings back that: 220 kA at 240 V, 154 kA at 415 V, 75.6 kA at 440 V, 30 kA at 500 V, 17 kA at 690 V. Rated continuous current is 200 A at 40 °C, and it holds that figure through 50 °C — only starts derating at 55 °C (194 A), dropping to 176 A at 70 °C. The TM220 designation on the overcurrent release means it's a thermal-magnetic trip unit fixed at 200 A — no interchangeable rating plugs, no electronic adjustment. For a sourcing decision, that locks the breaker to a 200 A feeder; if the BOM calls for a different amp rating, this isn't the variant.

Dimensions are 105 mm wide, 158 mm high, 70 mm deep — a standard 3-pole MCCB footprint for a 200 A frame. No undervoltage release, no shunt trip, no communication function — this is a straight electromechanical breaker with a manual handle and a trip indicator (which is absent on this variant). If the spec calls for remote tripping or status feedback, you'd need a different 3VA option with the accessory slot populated.

MPN
3VA1220-6EE32-0AA0