Siemens 3VA1463-5EF42-0AB0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA1463-5EF42-0AB0 SENTRON MCCB, 630 A, 187 kA

MPN3VA1463-5EF42-0AB0

Siemens SENTRON 3VA1463-5EF42-0AB0, molded case circuit breaker, 4-pole, 630 A, 187 kA at 240 V, TM240 overcurrent release, 2 auxiliary switches HP, IP40 front.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

3VA1463-5EF42-0AB0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA14635EF420AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA11
3VA1463-5EF42-0AB0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C630 A
Current at 45 °C630 A
Current at 50 °C630 A
Current at 55 °C618 A
Current at 60 °C607 A
Current at 65 °C595 A
Current at 70 °C583 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 690 V11.9 kA
3VA1463-5EF42-0AB0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM240
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA1463-5EF42-0AB0 — Construction & Connection
ParameterValue
Main circuit connection typelug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA1463-5EF42-0AB0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts2
3VA1463-5EF42-0AB0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA1463-5EF42-0AB0 — Mechanical
ParameterValue
Height210 mm
Width (in)7.2 in
Depth (in)4.3 in

Product details

630 A MCCB with 187 kA interrupting capacity

The Siemens SENTRON 3VA1463-5EF42-0AB0 is a 4-pole molded case circuit breaker rated for continuous current of 630 A at 40 °C, with a TM240 thermal-magnetic overcurrent release. Its interrupting capacity reaches 187 kA at 240 V AC — that is the figure that governs fault clearing at typical distribution voltages; at 415 V it still holds 121 kA, and at 690 V it derates to 11.9 kA.

Thermal derating and auxiliary configuration

Above that it drops linearly: 618 A at 55 °C, 607 A at 60 °C, 595 A at 65 °C, and 583 A at 70 °C. The breaker ships with two auxiliary switches (HP type) pre-installed, which saves a panel-builder the step of adding a separate aux block. That keeps the bill of materials lean for a straightforward line-protection role.

The breaker measures 210 mm tall, 7.2 in wide, and 4.3 in deep — a standard SENTRON 3VA frame size that fits the same mounting footprint as other 630 A 4-pole units in the family. Front face is IP40, which is typical for a panel-mounted MCCB; no special sealing for washdown. The 800 V rated insulation voltage (Ui) and 600 V DC max operational voltage (Ue) cover most industrial distribution voltages including 480/277 V and 600 V systems.

Frequently asked questions

What is the breaking capacity of 3VA1463-5EF42-0AB0 at 240 V?

187 kA at 240 V AC, with 121 kA at 415 V and 11.9 kA at 690 V.

Where can I buy 3VA1463-5EF42-0AB0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing are confirmed at quote time.

What is the height of 3VA1463-5EF42-0AB0?

210 mm.

What overcurrent release does 3VA1463-5EF42-0AB0 use?

A TM240 thermal-magnetic release — fixed, non-electronic, no communication function.

MPN
3VA1463-5EF42-0AB0