Siemens 3VA1463-6GF42-0AA0-ZD00 Circuit Breaker, 630A, 70kA

MPN3VA1463-6GF42-0AA0-ZD00

Siemens 3VA1 IEC frame 630 circuit breaker, breaking capacity class H, Icu=70kA @ 415V, 4-pole, line protection TM240 ATAM, In=630A, overload protection Ir=440A...630A, short-circuit protection Ii=4...8 x In, N conductor protection 100%.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Product details

Siemens 3VA1463-6GF42-0AA0-ZD00 — 630A IEC Frame Breaker with 70kA Breaking Capacity

The Siemens 3VA1463-6GF42-0AA0-ZD00 is a 4-pole IEC frame 630 circuit breaker in the 3VA1 series, rated for a breaking capacity class H with Icu=70kA at 415V. Overload protection is set via the TM240 ATAM trip unit, adjustable Ir from 440A to 630A, and short-circuit pickup Ii adjustable 4 to 8 times In. The N conductor is protected at 100%.

The 70kA Icu at 415V puts this breaker in class H — the highest standard breaking capacity for the 3VA1 frame. The TM240 ATAM thermal-magnetic trip gives you a continuous current rating of 630A with an overload adjustment band of 440A to 630A, so you can dial in the exact motor or feeder load without swapping trip units. The short-circuit magnetic pickup at 4 to 8 times In (2,520A to 5,040A) lets you ride through motor inrush while still clearing a bolted fault fast. The 4-pole construction with 100% N protection means it's suited for three-phase plus neutral systems where the neutral carries full phase current — common in data center PDUs or UPS output panels.

Deployment Context

At 630A frame size, it's a main breaker or large feeder breaker — not a branch device. The nut keeper kit noted in the description (for DC Power OEM in China) suggests this particular variant includes hardware for secure bolted connections on the line and load side, which is standard for high-current terminations where vibration or thermal cycling could loosen lugs.

Frequently asked questions

Where can I buy 3VA1463-6GF42-0AA0-ZD00 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ with your quantity and target price; availability and current pricing are confirmed at quote time.

What is the breaking capacity of this Siemens 3VA1 breaker?

It has a breaking capacity class H with Icu=70kA at 415V AC. That's the maximum short-circuit current it can safely interrupt at that voltage.

What are the overload and short-circuit protection settings on the 3VA1463-6GF42-0AA0-ZD00?

Overload protection (Ir) is adjustable from 440A to 630A via the TM240 ATAM trip unit. Short-circuit protection (Ii) is adjustable from 4 to 8 times In (2,520A to 5,040A).