Siemens 3VA2025-4HL42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2025-4HL42-0AA0 SENTRON MCCB, 4P, 25 A, ETU320, 1

MPN3VA2025-4HL42-0AA0

Siemens SENTRON 3VA2025-4HL42-0AA0, molded case circuit breaker, 4-pole, 25 A rated continuous current, ETU320 electronic overcurrent release, line protection version, interrupting capacity 121 kA at 240 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2025-4HL42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2025-4HL42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C25 A
Current at 60 °C25 A
Current at 65 °C25 A
Current at 70 °C25 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V76 kA
Breaking capacity at 440 V76 kA
Breaking capacity at 500 V53 kA
Breaking capacity at 690 V3 kA
Power loss, max.0.84 W
3VA2025-4HL42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2025-4HL42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2025-4HL42-0AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2025-4HL42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-40 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2025-4HL42-0AA0 — Mechanical
ParameterValue
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.1 in
Width (in)5.5 in
Depth (in)3.4 in

Product details

The Siemens SENTRON 3VA2025-4HL42-0AA0 is a 4-pole molded case circuit breaker rated for 25 A continuous current across the full ambient range from 40 °C to 70 °C — no derating curve to chase. That 25 A holds flat at every temperature step in the operating band, which simplifies panel thermal budgeting for a line-up of breakers in a closed cabinet. Interrupting capacity hits 121 kA at 240 V and 76 kA at 415/440 V, then drops to 53 kA at 500 V and 3 kA at 690 V. The 121 kA figure at 240 V covers high-fault utility or transformer-secondaries; the 76 kA at 415 V is the number most plant-floor distribution engineers will check first for IEC 60947-2 coordination studies. It carries the ETU320 electronic overcurrent release with an adjustable time delay tr from 0.5 to 17 s and N-conductor protection configurable as OFF or 100% of the phase rating. That adjustability lets you shape the trip curve to match downstream load inrush without oversizing the breaker. Power loss is only 0.84 W maximum — negligible in a densely packed distribution panel.

Dimensions: 181 mm height, 140 mm width, 86 mm depth. The 4-pole width (140 mm) is the standard 4-module MCCB footprint for this frame size — verify existing panel cutout and busbar centers against those numbers before ordering. No IP rating on the rear or sides; the breaker relies on the enclosure for overall ingress protection.

What the ETU320 release gives you

The ETU320 is a basic electronic trip unit with L (long-time) and I (instantaneous) protection — no ground-fault, no communication, no measurement. The tr adjustment range of 0.5 to 17 s lets you coordinate with downstream feeders or motor-start profiles without a more expensive trip unit.