Skip to main content
Siemens 3VA2125-0KP42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2125-0KP42-0AA0 SENTRON MCCB, 25A, 4-Pole, ETU850

MPN3VA2125-0KP42-0AA0
Active

Siemens SENTRON 3VA2125-0KP42-0AA0, molded case circuit breaker, 4-pole, 25 A continuous, ETU850 electronic trip unit, 690 V AC, IP40 front, line protection design.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2125-0KP42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
3VA2125-0KP42-0AA0 — Ratings
ParameterValue
Number of poles4
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C25 A
Current at 45 °C25 A
Current at 50 °C25 A
Current at 55 °C25 A
Current at 60 °C25 A
Current at 65 °C25 A
Current at 70 °C25 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.0.5 W
3VA2125-0KP42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU850
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2125-0KP42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2125-0KP42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2125-0KP42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2125-0KP42-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width140 mm
Depth86 mm
Height (in)7.13 in
Width (in)5.51 in
Depth (in)3.39 in

Product details

SENTRON 3VA2 MCCB, 25 A, 4-Pole — Line Protection with ETU850

The N-conductor protection is adjustable from OFF to 40%–160% of the phase rating, giving flexibility for systems where neutral current may exceed phase current (harmonic-rich loads). No ground-fault monitoring version is included on this order code — that's a separate variant if you need GF protection integrated.

Dimensions are 181 mm height, 140 mm width, 86 mm depth — a standard 4-pole MCCB footprint for the 3VA2 frame. Verify the 86 mm depth leaves clearance for outgoing cable bends and the ETU850's auxiliary wiring if communication function is used.

Trip Unit and Protection Capabilities

The ETU850 electronic trip unit supports communication function. Power loss is 0.5 W maximum. No undervoltage release or voltage trigger is included on this variant — those are separate accessories if needed for your application. The trip indicator is also not present on this order code, so visual trip status requires an optional auxiliary contact.

Frequently asked questions

Does the 3VA2125-0KP42-0AA0 include ground-fault protection?

No, this order code is the 'without' ground-fault monitoring version. If ground-fault protection is required, select a variant with that function or add an external GF relay.

MPN
3VA2125-0KP42-0AA0