Skip to main content
Siemens 3VA2140-5MN32-0AJ0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2140-5MN32-0AJ0 SENTRON MCCB, 40A, 3-Pole, 187kA

MPN3VA2140-5MN32-0AJ0

Siemens SENTRON 3VA series, molded case circuit breaker, 3VA2140-5MN32-0AJ0, 40 A rated, 3-pole, 187 kA at 240 V, motor protection design.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2140-5MN32-0AJ0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Basic switch (supplied) ref.3VA21405MN320AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AB11
3VA2140-5MN32-0AJ0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C40 A
Current at 45 °C40 A
Current at 50 °C40 A
Current at 55 °C40 A
Current at 60 °C40 A
Current at 65 °C40 A
Current at 70 °C40 A
Switching capacity classE
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V3.7 kA
Power loss, max.1.6 W
3VA2140-5MN32-0AJ0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU350M
Overcurrent protection functionLSI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA2140-5MN32-0AJ0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2140-5MN32-0AJ0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorYes
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts3
3VA2140-5MN32-0AJ0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2140-5MN32-0AJ0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.25 000
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

What this MCCB does for a motor circuit

The Siemens SENTRON 3VA2140-5MN32-0AJ0 is a 3-pole molded case circuit breaker (MCCB) rated for 40 A continuous current across the full ambient range from 40 °C to 70 °C — no derating needed up to the 70 °C ceiling. Its interrupting capacity sits at 187 kA at 240 V, 121 kA at 415 V and 440 V, 75.6 kA at 500 V, and 3.7 kA at 690 V, which covers most low-voltage distribution and motor branch circuits you'll encounter in an industrial panel.

Motor protection and phase loss coverage

This breaker is explicitly designed for motor protection, with built-in phase failure detection — meaning it will trip on a lost phase before the motor overheats from single-phasing. The trip indicator confirms the breaker opened on a fault, not a manual disconnect.

The 1.6 W maximum power loss is low enough that internal enclosure heating is negligible for most cabinet sizes.

Environmental tolerance

That covers unheated warehouses and outdoor-rated enclosures in most climates.

Frequently asked questions

How do I get current pricing and availability for 3VA2140-5MN32-0AJ0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm number.

What is 3VA2140-5MN32-0AJ0's interrupting capacity at 415 V?

The interrupting capacity at 415 V is 121 kA, matching the 440 V rating. At 500 V it drops to 75.6 kA, and at 690 V to 3.7 kA.

Will 3VA2140-5MN32-0AJ0 drop into a panel that was specified around 3VA2163-5HL32-0DB0 without rewiring?

Both are 3-pole SENTRON 3VA MCCBs sharing the same 105 mm width, 181 mm height, and 86 mm depth footprint, so the mechanical fit is identical. The electrical difference is in the trip curve and interrupting rating — verify the 3VA2163-5HL32-0DB0's trip characteristics match your coordination study before swapping.

MPN
3VA2140-5MN32-0AJ0