Skip to main content
Siemens 3VA2163-0MQ36-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2163-0MQ36-0AA0 SENTRON MCCB, 63 A, 440 kA

MPN3VA2163-0MQ36-0AA0
Active

Siemens SENTRON 3VA2163-0MQ36-0AA0, molded case circuit breaker, motor protection, 3-pole, 63 A, 440 kA at 415 V, ETU860M trip unit.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2163-0MQ36-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionMotor protection
3VA2163-0MQ36-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Rated insulation voltage Ui800 V
Current at 40 °C63 A
Current at 45 °C63 A
Current at 50 °C63 A
Current at 55 °C63 A
Current at 60 °C63 A
Current at 65 °C63 A
Current at 70 °C63 A
Switching capacity classE
Breaking capacity at 415 V440 kA
Breaking capacity at 690 V187 kA
Power loss, max.3.1 W
3VA2163-0MQ36-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU860M
Overcurrent protection functionLSIG
Ground-fault monitoringSummation current formation L-conductor
3VA2163-0MQ36-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typedouble-sided box terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2163-0MQ36-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionYes
Measurement functionYes
Motor drive optionYes
Auxiliary CO contacts0
3VA2163-0MQ36-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2163-0MQ36-0AA0 — Mechanical
ParameterValue
Height181 mm
Width105 mm
Depth86 mm
Height (in)7.13 in
Width (in)4.13 in
Depth (in)3.39 in

Product details

That's a serious SCCR figure — you can place this breaker at the main or a large subfeed in an industrial distribution panel and still coordinate downstream.

Trip unit and protection functions

The ETU860M electronic trip unit gives you adjustable trip classes: 10A, 10/10E, 20/20E, and 30/30E. That range covers fast-clearing for short motor leads up to slower curves for high-inertia loads like fans or centrifuges. The I²t trip is adjustable, and the breaker includes a communication function for integration into a higher-level monitoring system. That's useful for a plant-wide power management scheme where you want trip events and load data pulled back to a SCADA or energy dashboard.

Frequently asked questions

What is the breaking capacity of 3VA2163-0MQ36-0AA0?

It is rated 440 kA at 415 V and 187 kA at 690 V, making it suitable for high-fault-current industrial mains or subfeeds.

What trip classes does the ETU860M offer?

The adjustable trip classes are 10A, 10/10E, 20/20E, and 30/30E, covering fast motor protection through high-inertia loads.

Where can I buy 3VA2163-0MQ36-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

Will 3VA2163-0MQ36-0AA0 drop into a panel specified for 3VA2163-8HM32-0AA0?

Both are 3-pole SENTRON 3VA2 frame MCCBs with the same 105 mm width, 181 mm height, and 86 mm depth, so the physical footprint is identical. The difference is in the trip unit and protection functions — verify the protective settings match your coordination study before swapping.

MPN