Siemens 3VA2340-4HM42-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA2340-4HM42-0AA0 SENTRON MCCB, 400 A, 4-Pole, ETU3

MPN3VA2340-4HM42-0AA0

Siemens SENTRON 3VA2 series, molded case circuit breaker, 3VA2340-4HM42-0AA0, 4-pole, 400 A, ETU330 electronic trip unit, line protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2340-4HM42-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VA2340-4HM42-0AA0 — Ratings
ParameterValue
Number of poles4
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classS
Breaking capacity at 240 V121 kA
Breaking capacity at 415 V75.6 kA
Breaking capacity at 440 V75.6 kA
Breaking capacity at 500 V52.5 kA
Breaking capacity at 690 V7.5 kA
Power loss, max.96 W
3VA2340-4HM42-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU330
Overcurrent protection functionLIG
Ground-fault monitoringSummation current formation L + N conductor
3VA2340-4HM42-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeon both sides nut keeper kit
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-4HM42-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts0
3VA2340-4HM42-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-4HM42-0AA0 — Mechanical
ParameterValue
Height248 mm
Width184 mm
Depth110 mm
Height (in)9.76 in
Width (in)7.24 in
Depth (in)4.33 in

Product details

The Siemens 3VA2340-4HM42-0AA0 is a 4-pole SENTRON molded case circuit breaker rated for a continuous current Iu of 400 A at 40 °C, holding that rating flat through 50 °C before it starts to derate — 385 A at 55 °C, 370 A at 60 °C, 355 A at 65 °C, and 340 A at 70 °C. The interrupting ratings tell you where this breaker can sit in the fault-current hierarchy: 121 kA at 240 V, 75.6 kA at 415 V and 440 V, 52.5 kA at 500 V, and 7.5 kA at 690 V. ETU330 electronic trip unit for line protection. N-conductor protection adjustable to OFF, 50%, or 100% of phase current. Rated insulation voltage 800 V.

The breaker measures 184 mm wide × 248 mm high × 110 mm deep. The 4-pole width (184 mm) is the standard for a 400 A frame in the 3VA2 family — it occupies four 45 mm module positions on a DIN rail or bolted to a mounting plate. The depth of 110 mm means it clears most standard enclosure back-panels without a sub-panel extension. The ETU330 is a basic electronic trip with no communication function, so all settings are adjusted via the rotary dials on the front face.

Maximum power loss is 96 W at rated current. The 96 W loss is at 400 A; at partial load the I²R losses drop proportionally.

Frequently asked questions

What trip unit does this MCCB use?

An ETU330 electronic trip unit configured for line protection — no ground-fault or voltage-trip function. The N-conductor protection is adjustable to OFF, 50%, or 100% of phase current.

MPN
3VA2340-4HM42-0AA0