Skip to main content
Siemens 3VA2340-5HL32-0AE0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA2340-5HL32-0AE0 MCCB, 400 A, 3-Pole, Line

MPN3VA2340-5HL32-0AE0

Siemens SENTRON 3VA2340-5HL32-0AE0, 3-pole molded case circuit breaker, 400 A rated continuous current, line protection, ETU320 electronic trip unit, 187 kA breaking capacity at 240 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA2340-5HL32-0AE0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
Basic switch (supplied) ref.3VA2340-5HL32-0AA0
Integrated auxiliary / alarm switch ref.3VA9988-0AA12
3VA2340-5HL32-0AE0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C400 A
Current at 45 °C400 A
Current at 50 °C400 A
Current at 55 °C385 A
Current at 60 °C370 A
Current at 65 °C355 A
Current at 70 °C340 A
Switching capacity classM
Breaking capacity at 240 V187 kA
Breaking capacity at 415 V121 kA
Breaking capacity at 440 V121 kA
Breaking capacity at 500 V75.6 kA
Breaking capacity at 690 V17 kA
Power loss, max.96 W
3VA2340-5HL32-0AE0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeETU320
3VA2340-5HL32-0AE0 — Construction & Connection
ParameterValue
Main circuit connection typeLug terminal
Main circuit connector arrangementFront terminal
Protection class (IP), frontIP40
3VA2340-5HL32-0AE0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionYes
Auxiliary CO contacts4
3VA2340-5HL32-0AE0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA2340-5HL32-0AE0 — Mechanical
ParameterValue
Height248 mm
Width138 mm
Depth110 mm

Product details

The ETU320 electronic overcurrent release provides adjustable protection curves — a solid choice for feeding a main distribution board or a large motor control center, where you need to coordinate selectivity downstream.

Breaking capacity is what decides whether this breaker survives a fault without welding its contacts. At 240 V it clears 187 kA (cites:); at 415 V and 440 V it holds 121 kA (cites:,); at 500 V it drops to 75.6 kA (cites:); at 690 V it still manages 17 kA (cites:). Thermal derating matters when the panel runs hot. The 3VA2340-5HL32-0AE0 holds its full 400 A up to 50 °C (cites:,). At 55 °C it derates to 385 A (cites:); at 60 °C to 370 A (cites:); at 65 °C to 355 A (cites:); at 70 °C to 340 A (cites:). In a sealed enclosure with poor airflow, plan for the 50 °C threshold — above that, you lose headroom.

Four auxiliary switches (HQ type) are integrated (cites:), which saves an external interposing relay for status feedback to the PLC.

Frequently asked questions

Where can I buy 3VA2340-5HL32-0AE0?

This part is sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

What is the breaking capacity of 3VA2340-5HL32-0AE0 at 415 V?

121 kA at 415 V (cites:).

What trip unit does 3VA2340-5HL32-0AE0 use?

It uses the ETU320 electronic overcurrent release (cites:).

MPN