Siemens 3VA4110-5ED34-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA4110-5ED34-0AA0 SENTRON MCCB, 100 A, 85 kA at 240

MPN3VA4110-5ED34-0AA0
Active

Siemens SENTRON 3VA4110-5ED34-0AA0, 3-pole molded-case circuit breaker, 100 A at 40 °C, 85 kA interrupting at 240 V, TM210 release, system protection design.

$147.32Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA4110-5ED34-0AA0 — Identification
ParameterValue
Product designationMolded-case circuit breaker
Brand / rangeSENTRON
3VA4110-5ED34-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Current at 40 °C100 A
Current at 45 °C98 A
Current at 50 °C96 A
Current at 55 °C93 A
Current at 60 °C91 A
Current at 65 °C89 A
Current at 70 °C87 A
Switching capacity classM
Breaking capacity at 240 V85 kA
Power loss, max.22.8 W
3VA4110-5ED34-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA4110-5ED34-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeInfeed side: Low tab
Protection class (IP), frontIP40
3VA4110-5ED34-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA4110-5ED34-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA4110-5ED34-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height129.4 mm
Width76.2 mm
Depth75.1 mm
Height (in)5.09 in
Width (in)3 in
Depth (in)2.96 in

Product details

The Siemens 3VA4110-5ED34-0AA0 is a 3-pole SENTRON molded-case circuit breaker rated 100 A at 40 °C, with an interrupting capacity of 85 kA at 240 V AC and 35 kA at 480 V AC. No ground-fault monitoring, no undervoltage release, no communication module — this is a straight system-protection breaker sized for main or feeder duty where you don't need aux electronics.

The 100 A rating holds only at 40 °C ambient inside the enclosure. At 50 °C it's 96 A; at 60 °C it drops to 91 A; at 70 °C it's 87 A. The maximum power loss of 22.8 W is what the enclosure has to vent; that's modest for a 100 A frame, but in a sealed box with other breakers it adds up. Dimensions are 76.2 mm wide (3 in), 129.4 mm tall, 75.1 mm deep. That's a standard SENTRON 3VA4 frame footprint — it fits the same panel cutout and bus-bar spacing as the rest of the 3VA4 family. The IP40 front protection means it's splash-proof from the front face but not sealed; keep it inside the enclosure, not on the panel door.

Frequently asked questions

What is the interrupting rating of 3VA4110-5ED34-0AA0 at 480 V?

35 kA at 480 V AC, and 35 kA at 480Y/277 V. At 600Y/347 V it's 18 kA.

What are the ambient temperature derating steps for this breaker?

100 A at 40 °C, 98 A at 45 °C, 96 A at 50 °C, 93 A at 55 °C, 91 A at 60 °C, 89 A at 65 °C, 87 A at 70 °C.

Where can I buy 3VA4110-5ED34-0AA0?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3VA4110-5ED34-0AA0