Skip to main content
Siemens 3VA4130-6ED34-0AA0 — Molded Case Circuit Breakers (MCCB)

Siemens SENTRON 3VA4130-6ED34-0AA0 MCCB, 30A, 100kA at 240V

MPN3VA4130-6ED34-0AA0
Active

Siemens SENTRON 3VA4130-6ED34-0AA0, molded-case circuit breaker, 3-pole, TM210 overcurrent release, rated 30 A at 40 °C, interrupting capacity 100 kA at 240 V AC, 65 kA at 480 V AC.

$124.46Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA4130-6ED34-0AA0 — Identification
ParameterValue
Product designationMolded-case circuit breaker
Brand / rangeSENTRON
3VA4130-6ED34-0AA0 — Ratings
ParameterValue
Number of poles3
Rated operational voltage Ue (AC)690 V
Current at 40 °C30 A
Current at 45 °C29 A
Current at 50 °C29 A
Current at 55 °C28 A
Current at 60 °C27 A
Current at 65 °C27 A
Current at 70 °C26 A
Switching capacity classH
Breaking capacity at 240 V100 kA
Power loss, max.9 W
3VA4130-6ED34-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
Grounding protection functionNo
3VA4130-6ED34-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typeInfeed side: Low tab
Protection class (IP), frontIP40
3VA4130-6ED34-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA4130-6ED34-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA4130-6ED34-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height129.4 mm
Width76.2 mm
Depth75.1 mm
Height (in)5.09 in
Width (in)3 in
Depth (in)2.96 in

Product details

The Siemens SENTRON 3VA4130-6ED34-0AA0 is a 3-pole molded-case circuit breaker (MCCB) with a TM210 thermal-magnetic overcurrent release, designed for system protection in distribution panels and motor branch circuits. It carries a continuous current rating of 30 A at 40 °C, derating to 26 A at 70 °C — a curve worth checking if the panel runs hot. The interrupting capacity is 100 kA at 240 V AC and 65 kA at 480 V AC, which gives solid SCCR headroom for most industrial service-entrance and feeder applications.

At 240 V AC this breaker clears 100 kA symmetrical — that's full-rated for a 100 kA SCCR panel. At 480 V AC it still handles 65 kA, which covers most 480 V distribution boards without an upstream current-limiting fuse. The 65 kA figure repeats at 480Y/277 V; at 600Y/347 V it drops to 25 kA, so check the available fault current if the system runs at 600 V class.

At 45 °C it's 29 A, at 55 °C it's 28 A, at 70 °C it's 26 A. Operating range is -25 °C to 70 °C; storage from -40 °C to 80 °C. Front IP40 means it's splash-resistant in the panel face but not washdown-rated.

Frequently asked questions

Where can I buy 3VA4130-6ED34-0AA0 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Submit an RFQ for current availability and pricing.

What is the interrupting capacity of this MCCB at 480 V?

At 480 V AC (and 480Y/277 V) the interrupting capacity is 65 kA symmetrical.

MPN
3VA4130-6ED34-0AA0