Siemens 3VA4130-6ED34-1AA0 — Molded Case Circuit Breakers (MCCB)

Siemens 3VA4130-6ED34-1AA0 SENTRON MCCB, 30 A, 100 kA at 240

MPN3VA4130-6ED34-1AA0
Active

Siemens SENTRON 3VA4130-6ED34-1AA0, 3-pole molded-case circuit breaker, 30 A, 100 kA at 240 V, TM210 thermal-magnetic release, LI protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VA4130-6ED34-1AA0 — Identification
ParameterValue
Product designationMolded-case circuit breaker
Brand / rangeSENTRON
Product versionSystem protection
3VA4130-6ED34-1AA0 — Ratings
ParameterValue
Number of poles3
Current at 40 °C30 A
Current at 45 °C30 A
Current at 50 °C30 A
Current at 55 °C29 A
Current at 60 °C29 A
Current at 65 °C28 A
Current at 70 °C27 A
Switching capacity classH
Breaking capacity at 240 V100 kA
Power loss, max.9 W
3VA4130-6ED34-1AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VA4130-6ED34-1AA0 — Construction & Connection
ParameterValue
Main circuit connection typeInfeed side: Low tab
Main circuit connector arrangementLoad side: Circular conductor terminal
Protection class (IP), frontIP40
3VA4130-6ED34-1AA0 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VA4130-6ED34-1AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VA4130-6ED34-1AA0 — Mechanical
ParameterValue
Height129.4 mm
Width76.2 mm
Depth75.1 mm
Height (in)5.1 in
Width (in)3 in
Depth (in)3 in

Product details

The Siemens SENTRON 3VA4130-6ED34-1AA0 is a 3-pole molded-case circuit breaker rated 30 A continuous at 40 °C, with a TM210 thermal-magnetic release set for LI (long-time and instantaneous) protection. The instantaneous pickup is fixed at 300 A — no adjustment range, so it trips fast on a hard fault. At 65 kA at 480 V, this breaker can sit at the main lug of a panel fed from a 500 kVA transformer without worrying about cascading failure. The 100 kA at 240 V covers the worst-case bolted fault on a 208Y/120 V secondary — common in North American commercial and industrial switchboards.

At 55 °C it derates to 29 A, at 65 °C to 28 A, and at 70 °C to 27 A. That flat curve means you can pack it into a warm enclosure — say a non-ventilated panel near a drive or transformer — and still count on nearly full rating. The 76.2 mm width (3 in) and 75.1 mm depth (3 in) fit standard MCCB mounting footprints; the 129.4 mm height (5.1 in) clears most distribution panel gutters.

Frequently asked questions

What is the breaking capacity of 3VA4130-6ED34-1AA0 at 240 V and 480 V?

100 kA at 240 V and 65 kA at 480 V, making it suitable for high-fault-current panels.

What is the continuous current rating of 3VA4130-6ED34-1AA0?

30 A at 40 °C, with minimal derating up to 70 °C ambient.

Where can I buy 3VA4130-6ED34-1AA0?

Sourced and quoted to order against an RFQ through independent distribution; availability and current pricing confirmed at quote time.

MPN
3VA4130-6ED34-1AA0