Skip to main content
Siemens 3VM1010-3ED46-0AA2 — Molded Case Circuit Breakers (MCCB)

Siemens 3VM1010-3ED46-0AA2 SENTRON MCCB, 100 A, 76 kA at 240

MPN3VM1010-3ED46-0AA2

Siemens SENTRON 3VM1010-3ED46-0AA2, 4-pole molded case circuit breaker, 100 A continuous, TM210 release, 76 kA at 240 V AC.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VM1010-3ED46-0AA2 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VM1010-3ED46-0AA2 — Ratings
ParameterValue
Number of poles4
Current at 40 °C100 A
Current at 45 °C100 A
Current at 50 °C100 A
Current at 55 °C98 A
Current at 60 °C96 A
Current at 65 °C94 A
Current at 70 °C91 A
Switching capacity classN
Breaking capacity at 240 V76 kA
Breaking capacity at 415 V53 kA
Breaking capacity at 440 V32 kA
Breaking capacity at 500 V7.5 kA
Power loss, max.39 W
3VM1010-3ED46-0AA2 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
3VM1010-3ED46-0AA2 — Construction & Connection
ParameterValue
Main circuit connection typebox terminal
Main circuit connector arrangementFront connection
Protection class (IP), frontIP40
3VM1010-3ED46-0AA2 — Accessories & Functions
ParameterValue
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VM1010-3ED46-0AA2 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C

Product details

Siemens 3VM1010-3ED46-0AA2 — 100 A 4-Pole MCCB with TM210 Release

Its TM210 thermal-magnetic release provides LI protection (long-time and instantaneous), making it a straight line-protection device without ground-fault or communication functions. The interrupting ratings tell the real story here: 76 kA at 240 V AC, 53 kA at 415 V AC, 32 kA at 440 V AC, and 7.5 kA at 500 V AC. The 100 A frame is the maximum for this size class.

Panel Fit & Thermal Derating

The breaker uses box terminals for the main circuit, front-connected. That is the standard pattern for panel-mounted MCCBs — you land the cables on the front face, not a rear bus. Thermal derating is published: 100 A holds flat from 40 °C through 50 °C, then drops to 98 A at 55 °C, 96 A at 60 °C, 94 A at 65 °C, and 91 A at 70 °C. If your panel ambient runs 55 °C, you lose 2 A. That is tight but manageable — just do not assume the full 100 A at the top of the operating range. Rated insulation voltage is 690 V, and maximum operational voltage is 500 V AC (50/60 Hz) or 500 V DC. That 500 V DC rating is worth noting for battery-bank or UPS applications — not every MCCB carries a DC rating this high.

MPN
3VM1010-3ED46-0AA2