Siemens SENTRON 3VM1116-3ED22-0AA0, molded case circuit breaker, 2-pole, 160 A at 40 °C, 76 kA at 240 V, line protection.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

3VM1116-3ED22-0AA0 — Identification
ParameterValue
Product designationMolded case circuit breaker
Brand / rangeSENTRON
Product versionLine protection
3VM1116-3ED22-0AA0 — Ratings
ParameterValue
Number of poles2
Rated operational voltage Ue (AC)415 V
Rated insulation voltage Ui500 V
Current at 40 °C160 A
Current at 45 °C160 A
Current at 50 °C160 A
Current at 55 °C158 A
Current at 60 °C155 A
Current at 65 °C153 A
Current at 70 °C150 A
Switching capacity classN
Breaking capacity at 240 V76 kA
Breaking capacity at 415 V53 kA
Power loss, max.25 W
3VM1116-3ED22-0AA0 — Protection & Trip Unit
ParameterValue
Overcurrent release (trip unit) typeTM210
Overcurrent protection functionLI
Ground-fault monitoringWithout
3VM1116-3ED22-0AA0 — Construction & Connection
ParameterValue
Main circuit connection typenut keeper kit on both ends
Main circuit connector arrangementFront connection
Protection class (IP), frontIP40
3VM1116-3ED22-0AA0 — Accessories & Functions
ParameterValue
Undervoltage releaseNo
Voltage triggerNo
Trip indicatorNo
Communication functionNo
Measurement functionNo
Motor drive optionNo
Auxiliary CO contacts0
3VM1116-3ED22-0AA0 — Environmental
ParameterValue
Operating temperature, max.70 °C
Operating temperature, min.-25 °C
Storage temperature, max.80 °C
Storage temperature, min.-40 °C
3VM1116-3ED22-0AA0 — Mechanical
ParameterValue
Mechanical service life (operating cycles), typ.15 000
Height130 mm
Width50.8 mm
Depth70 mm
Height (in)5.12 in
Width (in)2 in
Depth (in)2.76 in

Product details

The Siemens SENTRON 3VM1116-3ED22-0AA0 is a 2-pole molded case circuit breaker (MCCB) rated 160 A at 40 °C, with a TM210 overcurrent release set for line protection (LI characteristic). It carries 76 kA breaking capacity at 240 V AC and 53 kA at 415 V AC — enough to clear high-fault conditions in distribution panels without cascading upstream. Rated insulation voltage is 500 V, maximum operating voltage 415 V AC, and DC operation up to 250 V is supported.

The 160 A rating holds flat from 40 °C through 50 °C. Above that, it derates gradually: 158 A at 55 °C, 155 A at 60 °C, 153 A at 65 °C, and 150 A at 70 °C. Operating ambient range is -25 °C to +70 °C; storage range is -40 °C to +80 °C.

The breaker measures 130 mm high, 50.8 mm wide, and 70 mm deep. The 50.8 mm width is a standard 2-inch footprint for a 2-pole MCCB — it will drop into a panel cutout or DIN-rail adapter designed for that pitch without rework.

Frequently asked questions

What are the key ratings for 3VM1116-3ED22-0AA0?

It is a 2-pole MCCB rated 160 A at 40 °C, with a breaking capacity of 76 kA at 240 V AC and 53 kA at 415 V AC. The overcurrent release is a TM210 with LI protection characteristic.

What is the depth of 3VM1116-3ED22-0AA0?

The depth is 70 mm (2.76 inches).

What is the width of 3VM1116-3ED22-0AA0?

The width is 50.8 mm (2 inches).

Where can I buy 3VM1116-3ED22-0AA0 and get current pricing?

This part is sourced to order against an RFQ through independent distribution. Submit a request for current pricing and availability — the quote will confirm real-time supply and price.

MPN
3VM1116-3ED22-0AA0