Skip to main content
Siemens 3RV1021-0JA10-ZW98

Siemens 3RV1021-0JA10-ZW98 SIRIUS Motor Circuit Breaker, 1 A

MPN 3RV1021-0JA10-ZW98

Siemens SIRIUS motor-protective circuit breaker, 3RV1021-0JA10-ZW98, 1 A rated current, Class 10 trip, 100 kA breaking capacity at 400 V, 3-pole, screw terminals, IP20 front, DIN rail mount.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3RV1021-0JA10-ZW98 specifications
ParameterValue
Depth96 mm
Width45 mm
Height97 mm
Trip classCLASS 10

Product details

SIRIUS 3RV1021-0JA10-ZW98 — Motor-Protective Circuit Breaker, 1 A, Class 10

The Siemens 3RV1021-0JA10-ZW98 is a SIRIUS motor-protective circuit breaker designed for 3-phase motor branch circuits, rated 1 A continuous current with Class 10 trip characteristic — meaning it clears an overload within 10 seconds at 7.2× rated current, matching the thermal time constant of standard induction motors up to 0.25 kW at 400 V. Breaking capacity reaches 100 kA across the full voltage range (240 V through 690 V AC), so it can interrupt worst-case fault currents without upstream coordination — a rare spec for a 45 mm wide device. Built-in phase-failure detection trips the breaker if one phase drops out, preventing single-phasing damage to the motor. No ground-fault detection on this variant.

Panel Integration & Mounting

Mounting position any; no derating for side-by-side placement (0 mm clearance required at sides and rear). Screw-type terminals on both main and auxiliary circuits accept solid or stranded conductors: 2×(1…2.5 mm²) and 2×(2.5…6 mm²) per clamp, or AWG 14–10.

RoHS compliance date 01.05.2012 confirms the part meets EU substance restrictions. Ambient operating range -20…+60 °C; storage/transport -50…+80 °C.

Duty Cycle & Thermal Management

Maximum operating frequency in AC-3 duty is 15 operations per hour — adequate for motor starting on pumps, fans, and compressors, but not for high-cycling applications like rapid reversing. Power dissipation at rated current: 7.25 W total, 2.4 W per pole in hot operating state. Rated impulse withstand voltage 6 kV, shock resistance 25 g / 11 ms — suitable for industrial environments with transient surges and mechanical vibration.

MPN
3RV1021-0JA10-ZW98