Skip to main content
Siemens 5SJ4318-8HG41 — 3-Pole MCB (DIN Rail)

Siemens 5SJ4318-8HG41 SENTRON MCB, 3P D-Curve, 400V AC

MPN5SJ4318-8HG41
Active

Siemens SENTRON 5SJ4 series, miniature circuit breaker, 3-pole, D characteristic, 400 V AC / 60 V DC, 10 kA (EN 60898) / 15 kA (IEC 60947-2), 70 mm depth, 54 mm width.

$124.46Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SJ4318-8HG41 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SJ4318-8HG41 — Protection
ParameterValue
Tripping characteristic (curve)D
Breaking capacity per EN 6089810 kA
Breaking capacity per IEC 60947-215 kA
Overvoltage category3
IP protection classIP20, with connected conductors, IP 40 in the handle range
Pollution degree3
5SJ4318-8HG41 — Electrical
ParameterValue
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)1.8 W
Mechanical service life (operating cycles, typ.)10 000
Neutral conductor switchingNo
5SJ4318-8HG41 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height110 mm
Depth70 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodon standard mounting rail
SealableYes
Accepts supplementary devicesYes
5SJ4318-8HG41 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Vibration resistance (IEC 60068-2-6)±1 mm at 5 to 25 Hz; 50 m/s² at 25 to 150 Hz

Product details

The Siemens 5SJ4318-8HG41 is a SENTRON 5SJ4 miniature circuit breaker — 3-pole, D tripping curve, rated 400 V AC and 60 V DC.

The D characteristic is the headline here — it's designed for circuits where the starting current can briefly hit 10–14 times the rated current before settling. That makes it a better fit for motor feeders, welding equipment, and heavy inductive loads than a B or C curve breaker, which would trip on the same inrush. Insulation voltage is rated at 440 V AC, so it's fine for 400 V line-to-line systems with margin. The 70 mm depth (installation depth matches) and 54 mm width (3 modular units) are the panel-fit dimensions you need for enclosure layout. It's sealable, halogen-free, and silicon-free — relevant for food, pharma, or clean-room environments where outgassing or contamination is a concern.

Frequently asked questions

What is the D tripping curve used for on this breaker?

The D characteristic allows the breaker to pass inrush currents up to 10–14 times the rated current without tripping, making it suitable for motor loads, transformers, and other inductive equipment where a B or C curve would nuisance-trip on startup.

What are the breaking capacities of 5SJ4318-8HG41?

Rated 10 kA per EN 60898 and 15 kA per IEC 60947-2. The higher IEC figure applies when the breaker is used in industrial installations per that standard.

Where can I buy 5SJ4318-8HG41 and get current pricing?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SJ4318-8HG41