Siemens 5SL4432-6 — 4-Pole MCB (DIN Rail)

Siemens 5SL4432-6 SENTRON MCB, 4P B 32A 10kA

MPN5SL4432-6
Active

Siemens SENTRON 5SL4432-6 miniature circuit breaker, 4-pole, tripping characteristic B, 32 A rated current, 10 kA breaking capacity at 400 V AC, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4432-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL4432-6 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC32 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
5SL4432-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-210 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
Touch protectionYes
5SL4432-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL4432-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL4432-6 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

Integrator note

The Siemens 5SL4432-6 is a 4-pole SENTRON miniature circuit breaker with B-curve tripping characteristic, rated 32 A at 30 °C and breaking 10 kA per both IEC 60898 and IEC 60947-2 at 400 V AC. With IP20 protection (finger-safe with conductors connected), it is intended for enclosed panel mounting, not open-wet locations.

Thermal derating and selectivity

The 32 A rating holds at 30 °C ambient but derates to 30.31 A at 40 °C and 27.58 A at 55 °C — a 14 % drop from the nameplate figure. For a panel running at 40 °C ambient, the effective continuous load limit is just over 30 A, not the full 32 A. That matters when coordinating with an upstream 40 A or 50 A device: the 5SL4432-6's 10 kA SCCR at 400 V gives headroom for most residential and light commercial fault levels, but the thermal derating curve must be factored into the load schedule.

Frequently asked questions

Where can I buy the 5SL4432-6 and get a price?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the 5SL4432-6's depth?

The listed depth is 76 mm, with an installation depth of 70 mm, fitting within a standard 100 mm deep enclosure.

What compliance documentation does Siemens provide for the 5SL4432-6?

The breaker is halogen-free, silicon-free, sealable for lockout/tagout, and carries IP20 touch protection with connected conductors. It is designed per IEC 60898 and IEC 60947-2 for residential and infrastructure use.