Skip to main content
Siemens 5SL4432-7RC — 4-Pole MCB (DIN Rail)

Siemens 5SL4432-7RC SENTRON MCB, 4P C 32A 10kA 415V

MPN5SL4432-7RC
Active

Siemens SENTRON 5SL4432-7RC, miniature circuit breaker, 4-pole, C characteristic, 32 A, 10 kA breaking capacity at 415 V AC, 1 MW width.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SL4432-7RC — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityResidential buildings/infrastructure
5SL4432-7RC — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated voltage, AC (multi-phase)440 V
5SL4432-7RC — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
5SL4432-7RC — Mechanical
ParameterValue
Width in modular units1
Width18 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SL4432-7RC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
5SL4432-7RC — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)2.73 W

Product details

The Siemens 5SL4432-7RC is a SENTRON miniature circuit breaker (MCB) — a 4-pole, C-curve unit rated 32 A with a 10 kA breaking capacity per EN 60898 at 415 V AC.

This MCB snaps onto a standard 35 mm DIN rail and occupies 1 modular width unit (18 mm) — that's the narrowest possible footprint for a 4-pole breaker, so it leaves room in a crowded panel. Depth is 76 mm, height 90 mm, and the installation depth behind the panel face is 70 mm. Mounting position is unrestricted, and the IP20 rating (with conductors connected) is typical for enclosed distribution boards — no special sealing needed inside a cabinet.

The 10,000 mechanical operating cycles typical service life means this breaker is built for the switching frequency of a distribution board — not a daily-switched load, but fine for occasional isolation and fault clearance. The 2.73 W power loss per pole at rated current in hot operating state adds up to about 11 W total for the 4-pole unit — negligible for thermal management in a standard enclosure, but worth noting if you're packing many breakers into a small, sealed box.

Frequently asked questions

Where can I buy the 5SL4432-7RC and how is it quoted?

We source the 5SL4432-7RC to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm quote on your volume.

Will the 5SL4432-7RC drop into a panel specified for the 5SL4363-7?

No — the 5SL4363-7 is a 3-pole unit in a 54 mm (3 MW) width, while the 5SL4432-7RC is 4-pole in 18 mm (1 MW). The pole count and physical footprint are different; the panel would need rewiring and a different DIN-rail layout.

What compliance documentation does Siemens provide for the 5SL4432-7RC?

The SENTRON series carries standard IEC/EN 60898-1 certification for the 10 kA breaking capacity. The part is halogen-free and silicon-free. For specific declarations (RoHS, REACH, UL), request the manufacturer's compliance documentation with your RFQ.

MPN
5SL4432-7RC