Skip to main content
Siemens 5SM2345-6KK12 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM2345-6KK12 4P RCCB Type A, 63A 30mA

MPN5SM2345-6KK12
Active

Siemens SENTRON 5SM2345-6KK12, 4-pole RCCB, Type A, In: 63 A, 30 mA, Un AC: 400 V, for 5SY, DIN rail mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SM2345-6KK12 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SM2345-6KK12 — Mechanical
ParameterValue
Mounting positionany
Width in modular units3
Maximum45 °C
Minimum-25 °C
Width124 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SM2345-6KK12 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens 5SM2345-6KK12 is a 4-pole residual current circuit breaker (RCCB) rated 63 A at 400 V AC, 50 Hz, with a 30 mA trip threshold and Type A sensitivity. The 63 A rating at 40 °C (58.6 A) and 45 °C (58.59 A) means this device carries the full load of a three-phase sub-distribution board or a large machine infeed without nuisance tripping from leakage — the 30 mA threshold catches sinusoidal AC and pulsating DC fault currents, covering most modern electronic loads (switched-mode power supplies, VFDs, rectifiers). Type A is the standard choice for circuits with single-phase rectification downstream — think PLC power supplies, lighting ballasts, or small drives.

The 124 mm width (3 modular units) and 77 mm depth with 70 mm installation depth mean it occupies three 18 mm slots in a distribution board — check your enclosure fill factor before committing the BOM line.

Temperature derating — the real-world rating

The 63 A nominal rating holds at 40 °C ambient. Above that, the continuous current drops: 58.6 A at 40 °C, 56.7 A at 50 °C, 53.55 A at 60 °C, and 50.4 A at 70 °C.

Frequently asked questions

What is the 5SM2345-6KK12 used for?

It is a 4-pole Type A RCCB rated 63 A and 30 mA, used for earth-fault protection in three-phase distribution boards, typically upstream of socket outlets, lighting circuits, or mixed loads with electronic equipment.

What are the key ratings of the 5SM2345-6KK12?

Rated current 63 A at 40 °C, 30 mA trip sensitivity, Type A, 4-pole, 400 V AC, 50 Hz, IP20, DIN rail mount. Derate to 56.7 A at 50 °C ambient.

Where can I buy the 5SM2345-6KK12?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SM2345-6KK12