Siemens 5SM2342-6 — Residual Current Breakers (RCCB/RCBO)

Siemens 5SM2342-6 SENTRON RCD, 4P 40A 30mA Type A

MPN5SM2342-6
Active

Siemens SENTRON 5SM2342-6 RCD-unit, 4-pole, 40 A rated current, 30 mA Type A instantaneous, IP20, 50 Hz.

$29.21Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SM2342-6 — Electrical Ratings
ParameterValue
Number of poles4
Overvoltage categoryIII
5SM2342-6 — Identification
ParameterValue
Product designationRCD-unit
Product design / constructioninstantaneous
5SM2342-6 — Mechanical
ParameterValue
Mounting positionany
Width in modular units3
Maximum75 °C
Minimum-40 °C
Width124 mm
Height90 mm
Depth77 mm
Installation depth70 mm
5SM2342-6 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

Residual current device for 5SY MCB integration

The Siemens 5SM2342-6 is a 4-pole RCD-unit from the SENTRON family, designed as an instantaneous Type A residual current device with a 30 mA trip threshold and 40 A rated current at AC. It mates mechanically and electrically with the 5SY series miniature circuit breakers to form a combined RCBO assembly in a distribution board.

Rated 40 A at AC, the unit derates progressively above 40 °C ambient: 37.2 A at 40 °C and 45 °C, 36 A at 50 °C, 34.8 A at 55 °C, 34 A at 60 °C, 33.2 A at 65 °C, and 32 A at 70 °C. In a crowded enclosure with multiple heat sources, use the 50 °C column (36 A) as the practical continuous rating. The fastening method is standard DIN-rail clip (REG).

The unit withstands a surge current of 1 kA and a surge voltage of 4 000 V, matching the impulse withstand requirements of a standard TN or TT system. Operating frequency is 50 Hz only. The minimum test voltage is 195 V, and the unit includes a protection function against false tripping (nuisance tripping suppression) for transient surge currents that would otherwise cause unwanted disconnection. The OFF-delay time is not adjustable — this is an instantaneous RCD, not a time-delayed (S-type) unit, so it trips within the standard cycle without intentional delay. The rated fault current is also fixed at 30 mA, not adjustable.

Frequently asked questions

What are the key ratings of the 5SM2342-6?

4-pole RCD, 40 A rated current at AC, 30 mA Type A instantaneous trip, 460 V insulation voltage, 50 Hz, IP20. Thermal derating applies above 40 °C ambient.

Where can I buy the 5SM2342-6?

This part is sourced and quoted to order against an RFQ through independent industrial-automation distribution. Current pricing and availability are confirmed at quote time.

What compliance documentation does Siemens provide for the 5SM2342-6?

The reference code per IEC 81346-2 is F. The unit is designed for overvoltage category III and pollution degree 2. Standard Siemens SENTRON documentation (CE declaration, RoHS/REACH compliance statements) is available on request.

MPN
5SM2342-6