Skip to main content
Siemens 5SM3321-4KK14 — Residual Current Breakers (RCCB/RCBO)

Siemens SENTRON 5SM3321-4KK14 RCCB, 2-pole, 16 A, 30 mA, Typ

MPN5SM3321-4KK14

Siemens SENTRON RCCB, 2-pole, 16 A rated, 30 mA trip, Type B+, short-time delayed, 10 kA SCCR, DIN rail mount, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SM3321-4KK14 — Electrical Ratings
ParameterValue
Number of poles2
Overvoltage categoryIII
5SM3321-4KK14 — Identification
ParameterValue
Product designationRCCB
Product design / constructionShort-time delayed
5SM3321-4KK14 — Mechanical
ParameterValue
Mounting positionany
Width in modular units4
Maximum45 °C
Minimum-25 °C
Width72 mm
Height90 mm
Depth70 mm
Installation depth70 mm
5SM3321-4KK14 — Environmental
ParameterValue
IP degree of protectionIP20, if the distribution board is installed, with connected conductors

Product details

The Siemens SENTRON 5SM3321-4KK14 is a 2-pole residual current circuit breaker (RCCB) rated at 16 A with a 30 mA trip threshold, designed for 50 Hz systems. Its Type B+ residual current characteristic means it detects AC, pulsating DC, smooth DC, and high-frequency AC residual currents — covering variable-speed drive leakage and inverter-fed loads that a standard Type A would miss. The short-time delayed design (selective / S-type) provides coordination with downstream RCCBs, so a fault on a branch trips the branch device before this main unit, keeping the rest of the panel live.

Mounts on DIN rail (REG) in any position, occupying 4 modular width units. Depth is 70 mm, width 72 mm, height 90 mm. Silicon-free construction suits environments where silicone outgassing can contaminate contacts or optics.

Rated short-circuit current (SCCR) is 10 kA per IEC 61008-1, with a lower 0.8 kA rating per EN 60898. The I²t let-through is 70 000 A²·s; surge current resistance is 3 kA. Overvoltage category III. Rated supply voltage frequency 50 Hz. The test circuit minimum voltage is 195 V. Supply connection can be top or bottom; for SIGRES function, bottom connection keeps the test circuit active even when the RCCB is switched off.

Rated current derates with ambient temperature: 16 A at 40 °C, 16 A at 45 °C, 15.04 A at 50 °C, 14.08 A at 55 °C, 13.12 A at 60 °C, 12.16 A at 65 °C, 11.2 A at 70 °C.

Frequently asked questions

Who supplies 5SM3321-4KK14 and how is it quoted for volume purchases?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is 5SM3321-4KK14's listed depth?

The depth is 70 mm.

What is 5SM3321-4KK14's listed width?

The width is 72 mm.

Will 5SM3321-4KK14 drop into a panel specified around 5SJ6325-7RC without rewiring?

No — 5SJ6325-7RC is a Siemens miniature circuit breaker (MCB), not an RCCB. The 5SM3321-4KK14 is a 2-pole RCCB with a 30 mA trip and Type B+ characteristic; the MCB provides overcurrent protection only. They serve different functions and are not drop-in interchangeable.

What compliance documentation does Siemens provide for 5SM3321-4KK14?

The part is designed to IEC 61008-1 and EN 60898 standards. Overvoltage category III. The evidence does not list RoHS, REACH, or UL documentation specifically for this order code.

MPN
5SM3321-4KK14