Siemens 5SY4325-6KK11 — 3-Pole MCB (DIN Rail)

Siemens 5SY4325-6KK11 SENTRON MCB, 3P B-Curve, 10kA IEC

MPN5SY4325-6KK11

Siemens SENTRON 5SY4325-6KK11, 3-pole miniature circuit breaker, B-curve, 10 kA (EN 60898-1) / 20 kA (IEC 60947-2), 400 V AC, 3 modular width units.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4325-6KK11 — Identification
ParameterValue
Brand nameSENTRON
Number of poles3
Pole configuration3P
Suitability for operationMechanical engineering / industry
5SY4325-6KK11 — Protection
ParameterValue
Tripping characteristic (curve)B
Breaking capacity per EN 6089810 kA
Breaking capacity per IEC 60947-220 kA
Overvoltage categoryIII
IP protection classIP20, with connected conductors
Energy limitation class3
Pollution degree3
5SY4325-6KK11 — Electrical
ParameterValue
Rated voltage (AC, multi-phase)440 V
Voltage type (AC/DC)AC
Supply frequency range50/60 Hz
Power loss per pole at rated current (AC, hot)2.4 W
Mechanical service life (operating cycles, typ.)10 000
Neutral conductor switchingNo
Rated voltage (AC, single-phase)440 V
5SY4325-6KK11 — Mechanical
ParameterValue
Modular width units3
Mounting positionany
Width54 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Terminal tightening torque, max.75 °C
Terminal tightening torque, min.-40 °C
Combined terminal, topYes
Combined terminal, bottomYes
Fastening methodQuick assembly system
SealableYes
Accepts supplementary devicesYes
5SY4325-6KK11 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of surrounding temperaturemax. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
Vibration resistance (IEC 60068-2-6)±1mm at 5 to 25Hz; 50m/s² at 25 to 150Hz

Product details

It is not intended for motor-starting duty (where C- or D-curves handle the higher inrush). Breaking capacity is dual-rated: 10 kA per EN 60898-1 and 20 kA per IEC 60947-2. The 20 kA figure under 60947-2 is the one that matters for industrial panel SCCR calculations — it tells you this MCB can safely interrupt a fault up to 20 kA at 400 V AC without welding contacts or cascading upstream. The 10 kA EN rating is the residential/commercial reference. Rated for 400 V AC (440 V max in multi-phase or single-phase operation), 50/60 Hz. DC rating is 60 V operating, 72 V max, with 15 kA breaking capacity per IEC 60947-2 — useful for DC auxiliary circuits in the same panel.

Frequently asked questions

Will 5SY4325-6KK11 drop into a panel specified around 5SY6332-7CC?

Both are 3-pole SENTRON MCBs on the same DIN-rail footprint (3 modular width units). The 5SY4325-6KK11 is a B-curve device; the 5SY6332-7CC is a different curve/rating variant. They share the same mechanical envelope and terminal arrangement, so no rewiring is needed for the panel layout — but verify the trip curve and current rating match the circuit protection requirements before swapping.

MPN