Skip to main content
Siemens 5SY4463-6 — 4-Pole MCB (DIN Rail)

Siemens 5SY4463-6 SENTRON MCB, 4P B 63A 10kA

MPN5SY4463-6
Active

Siemens SENTRON 5SY4463-6, a 4-pole B-curve miniature circuit breaker rated 63 A at 35 °C, 400 V AC, 10 kA breaking capacity per EN 60898 and 15 kA per IEC 60947-2.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4463-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4463-6 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC400 V
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Voltage typeAC
5SY4463-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-215 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes
5SY4463-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4463-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

The 5SY4463-6: Mounting position is any; the fastening method uses a quick-assembly system, and the unit is sealable for lockout/tagout compliance. Halogen-free and silicon-free construction, pollution degree 3, and IP20 finger-safe terminals with connected conductors.

Panel fit and sourcing posture

Fits standard SENTRON panel-mounting rails and knockouts.

Installation notes

Combined terminal at both top and bottom — feed-through wiring is straightforward. Position of supply cord is any; no orientation restriction. Overvoltage category III, typically for fixed-install panel feeders. If the panel ambient exceeds 35 °C, apply the derated current values given in the spec table — the 63 A rating is valid only at 35 °C.

Frequently asked questions

What are the physical dimensions of the 5SY4463-6?

Width is 72 mm (4 modular units), depth is 76 mm, installation depth is 70 mm, height is 90 mm.

MPN