Siemens 5SY4513-7 — 1-Pole MCB (DIN Rail)

Siemens 5SY4513-7 SENTRON MCB, 2-pole C-curve, 10/20 kA

MPN5SY4513-7
Active

Siemens SENTRON 5SY4513-7, miniature circuit breaker, 2-pole (1P+N), C tripping characteristic, 10 kA per EN 60898 / 20 kA per IEC 60947-2, 230 V AC, 2 MW wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4513-7 — Identification
ParameterValue
Product designationMiniature circuit breaker
Brand nameSENTRON
Number of poles2
Pole design1P+N
Application suitabilityMechanical engineering / industry
5SY4513-7 — Electrical & Protection
ParameterValue
Tripping characteristic classC
Energy limitation class3
Overvoltage categoryIII
5SY4513-7 — Mounting & Connection
ParameterValue
Mounting positionany
Fastening methodQuick assembly system
Combined terminal, topYes
Combined terminal, bottomYes
Width36 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Modular width units2
Torque, min.-40 °C
Torque, max.75 °C
SealableYes
5SY4513-7 — Environmental
ParameterValue
IP protection classIP20, with connected conductors
Pollution degree3
Halogen-freeYes
Silicone-freeYes

Product details

It switches the neutral conductor (1P+N) inside a 2-pole housing, so you get full isolation on both lines in a single 36 mm wide unit. Rated breaking capacity hits 10 kA under IEC/EN 60898-1 and 20 kA under IEC 60947-2, with a DC rating of 15 kA per IEC 60947-2 at 60 V. That dual-standard rating means it qualifies for both residential-distribution boards (EN 60898) and industrial panel schedules (IEC 60947-2) — one part, two compliance gates.

The combined terminal at top and bottom accepts the same conductor range; supply cord position is arbitrary, so you can feed from either end without flipping the breaker. Sealable terminals let you lock the cover after commissioning for tamper-proofing.

Halogen-free and silicon-free construction — no silicone outgassing to foul relay contacts or optical sensors in the same enclosure. Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz — survives shipping and moderate machine vibration.

Frequently asked questions

What is the breaking capacity of 5SY4513-7?

10 kA per IEC/EN 60898-1, 20 kA per IEC 60947-2 at 230 V AC, and 15 kA per IEC 60947-2 at 60 V DC.

Will 5SY4513-7 drop into a panel specified around 5SY4140-7?

Yes — both are 2-pole SENTRON MCBs on the same 36 mm footprint with identical DIN-rail mounting and terminal layout. The difference is the tripping characteristic: 5SY4513-7 is C-curve (5–10× In), while 5SY4140-7 is a different curve. If the panel design calls for C-curve, this is a direct swap.

Where can I buy 5SY4513-7 and how is it quoted?

Sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

MPN
5SY4513-7