Skip to main content
Siemens 5SY4610-6 — 4-Pole MCB (DIN Rail)

Siemens 5SY4610-6 SENTRON MCB, 4P, B-Curve, 10 A, 10 kA

MPN5SY4610-6
Active

Siemens SENTRON 5SY4610-6 miniature circuit breaker, 4-pole (3P+N), B tripping characteristic, 10 A rated current, 10 kA (EN 60898) / 20 kA (IEC 60947-2) breaking capacity.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4610-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4610-6 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC10 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
5SY4610-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Touch protectionYes
5SY4610-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4610-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4610-6 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

It breaks faults at 10 kA per EN 60898-1 and 20 kA per IEC 60947-2 / UL 1077, covering both residential and industrial panel applications.

The B-curve trips between 3 and 5 times rated current — 30 A to 50 A for this 10 A unit — making it a first-choice for resistive and general-purpose loads where inrush is moderate. The 4-module-width (72 mm) footprint fits standard DIN-rail enclosures; the quick-assembly fastening method and any mounting position simplify panel integration. Rated current derates with ambient temperature: 10 A at 35 °C, 9.52 A at 40 °C, down to 8.48 A at 60 °C.

The MCB is certified to IEC / EN 60898-1 and IEC / EN 60947-2 / UL 1077, covering both residential and industrial standards. The energy limitation class is 3, meaning it limits let-through energy effectively for downstream equipment protection.

Frequently asked questions

How do I get current pricing and availability for 5SY4610-6?

Submit an RFQ through this listing. The part is sourced to order via independent distribution; availability and pricing are confirmed at quote time.

What is the closest functional alternative to 5SY4610-6?

The 5SY4140-7 is a 4-pole B-curve MCB in the same SENTRON family, but it is a 40 A unit versus the 10 A 5SY4610-6. They share the same 4-module footprint and breaking capacity ratings, so a panel designed for one can accept the other without rewiring — only the overcurrent protection level changes.

What compliance documentation does Siemens provide for 5SY4610-6?

The MCB carries certifications to IEC / EN 60898-1, IEC / EN 60947-2, and UL 1077. It is halogen-free and silicon-free. Standard documentation includes the declaration of conformity and material compliance declarations on request.

MPN