Skip to main content
Siemens 5SY4610-8 — 4-Pole MCB (DIN Rail)

Siemens 5SY4610-8 SENTRON MCB, 4-pole D-curve 10 A, 10/20 kA

MPN5SY4610-8
Active

Siemens SENTRON 5SY4 series, miniature circuit breaker, 4-pole (3P+N), D tripping characteristic, 10 A rated, 400 V AC, 10 kA (EN 60898) / 20 kA (IEC 60947-2).

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY4610-8 — Identification
ParameterValue
Type / order code5SY4
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4610-8 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC400 V
Rated current (In), AC10 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY4610-8 — Protection
ParameterValue
Tripping characteristic (trip curve)D
Rated breaking capacity (Icn), per EN 6089810 kA
Rated breaking capacity, per IEC 60947-220 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY4610-8 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.31 lbf·in
Tightening torque, min.22 lbf·in
SealableYes
5SY4610-8 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4610-8 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens 5SY4610-8 is a SENTRON 5SY4-series miniature circuit breaker — 4-pole (3P+N), D-curve, 10 A rated current at 400 V AC.

For DC circuits it's rated 15 kA per IEC 60947-2 up to 72 V. UL 1077 / CSA C22.2 No. 235 recognition at 5 kA covers North American panel builds.

Frequently asked questions

What is the breaking capacity of 5SY4610-8?

10 kA per EN 60898, 20 kA per IEC 60947-2 at 400 V AC, and 15 kA per IEC 60947-2 at 72 V DC. UL 1077 / CSA rating is 5 kA.

Will 5SY4610-8 drop into a panel specified around 5SY4140-7 without rewiring?

Both are 4-pole SENTRON 5SY-series MCBs on the same DIN-rail footprint, so mechanical fit is identical. The difference is the tripping curve — 5SY4610-8 is D-curve (10–20× In), while 5SY4140-7 is B-curve (3–5× In). If the original design relied on B-curve selectivity, swapping to D-curve without coordination check risks nuisance tripping on fault; if the load is motor or transformer, D-curve is actually the better fit.

What compliance documentation does Siemens provide for 5SY4610-8?

The breaker carries EN 60898 and IEC 60947-2 ratings, plus UL 1077 and CSA C22.2 No. 235 recognition. It is halogen-free and silicon-free. Standard Siemens declarations of conformity (CE, UKCA) and material compliance (RoHS, REACH) are available on request.

Where can I buy 5SY4610-8?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

MPN