Siemens 5SY4610-7 — 4-Pole MCB (DIN Rail)

Siemens 5SY4610-7 SENTRON MCB, 4P C-curve, 10kA IEC/EN 60898

MPN5SY4610-7
Active

Siemens SENTRON 5SY4610-7, 4-pole miniature circuit breaker, C-curve, 10 kA (IEC 60898-1) / 20 kA (IEC 60947-2), 400 V AC, 60 V DC, 4 MW, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY4610-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY4610-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SY4610-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY4610-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY4610-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY4610-7 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.1 W

Product details

What it is and what it does

The Siemens 5SY4610-7 is a 4-pole (3P+N) miniature circuit breaker from the SENTRON series, designed for branch-circuit protection in industrial control panels and distribution boards. Its C-curve tripping characteristic means it handles moderate inrush currents — typical for motor starters, contactor coils, and small transformers — without nuisance tripping, while still clearing overloads and short circuits within the standard time-current band. Breaking capacity is rated at 10 kA per IEC/EN 60898-1 and 20 kA per IEC 60947-2, with a DC rating of 15 kA per IEC 60947-2 and 5 kA per UL 1077 / CSA C22.2 No.235. That spread covers most industrial and commercial fault levels; the 20 kA IEC 60947-2 figure is the one to use when coordinating with upstream devices in a selective scheme.

Mounting and integration

Occupies 4 modular-width units (72 mm) on a DIN rail. Depth is 76 mm, with 70 mm installation depth behind the panel. IP20 with connected conductors — standard for enclosed distribution boards; not rated for washdown or outdoor exposure without a secondary enclosure.

Lifecycle and compliance

Listed as current production. Compliance covers IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077. Halogen-free and silicon-free construction — relevant for clean-room or high-reliability environments where outgassing matters. Sealable for lockout/tagout procedures.

Frequently asked questions

What compliance documentation does Siemens provide for 5SY4610-7?

The breaker is certified to IEC/EN 60898-1, IEC/EN 60947-2, and UL 1077. It is halogen-free and silicon-free. Standard Siemens declarations (CE, UKCA, RoHS) are available on request.

MPN