Siemens 5SY5425-6 — 4-Pole MCB (DIN Rail)

Siemens 5SY5425-6 SENTRON MCB, 25 A, 4-Pole, B-Curve

MPN5SY5425-6
Active

Siemens SENTRON 5SY5 series, miniature circuit breaker, 4-pole, 25 A, B characteristic, 10 kA (EN 60898) / 15 kA (IEC 60947-2) breaking capacity, AC 400 V / DC 880 V rated voltage.

StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jul 2026

Specifications

Identification

5SY5425-6 — Identification
ParameterValue
Type / order code5SY5
Brand nameSENTRON
Application suitabilityuniversal current

Ratings

5SY5425-6 — Ratings
ParameterValue
Number of poles4
Pole configuration4P
Rated current (In), AC400 V
Rated current (In), AC25 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)1 000 V
Voltage typeAC/DC
Rated frequency50/60 Hz

Protection

5SY5425-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Rated breaking capacity (Icn), per EN 6089810 kA
Overvoltage categoryII
Pollution degree2
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingNo
Touch protectionYes

Mechanical

5SY5425-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes

Environmental

5SY5425-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Performance

5SY5425-6 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

Siemens 5SY5425-6 — 25 A 4-Pole B-Curve MCB for Universal-Current Circuits

The Siemens 5SY5425-6 is a SENTRON 5SY5-series miniature circuit breaker rated 25 A at 400 V AC and 880 V DC, with a B tripping characteristic that trips between 3 and 5 times rated current — the standard choice for resistive and general-purpose loads where inrush is moderate. Its 4-pole (4P) construction in a 4-module-wide housing (72 mm) covers three-phase-plus-neutral or DC circuits, and the universal-current design (AC/DC rated) means it handles both supply types without derating the frame. Breaking capacity sits at 10 kA per EN 60898 and 15 kA per IEC 60947-2 at DC — the higher figure under the industrial standard matters when the prospective fault current exceeds the domestic-grade limit. The B-curve keeps nuisance tripping low on lighting and control transformer circuits while still clearing a hard short within the let-through energy limits of the downstream wiring.

Mounting and Panel Fit

Snaps onto DIN rail via the quick-assembly system; 70 mm installation depth leaves room behind the breaker for wiring. The 72 mm width (4 width units at 18 mm each) is standard for a 4-pole MCB — no surprises when laying out a multi-row distribution board. Mounting position is any, so vertical or horizontal busbar arrangements work without derating. Combined top and bottom terminals accept incoming feed from either direction — useful when the busbar runs along the top but the panel layout forces a bottom feed. Touch protection is built in, and the sealable cover option (with conductors connected, IP20) satisfies lockout/tagout requirements on panels that need physical isolation verification.

Environmental and Compliance Notes

Rated for ambient temperatures from -40 °C to 75 °C, with humidity derating above 55 °C (95 % RH up to 55 °C, then 55 % RH to 70 °C, 35 % RH to 75 °C). Halogen-free and silicon-free construction suits clean-room or food-processing panels where outgassing contaminates sensitive optics or product. Pollution degree 2 (normal industrial environment, non-condensing).

DC Application Specifics

Rated DC voltage is 880 V (1-pole per string in series), with a maximum DC voltage of 1 000 V and breaking capacity of 15 kA per IEC 60947-2. The DC polarity must be observed when wiring — the supply cord position note says AC as required, but DC requires correct polarity. For a 4-pole breaker used in a bipolar DC circuit, two poles in series per polarity doubles the voltage withstand and arc-quenching margin.

Frequently asked questions

Where can I buy the 5SY5425-6 and get a price?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What is the breaking capacity of the 5SY5425-6?

10 kA per EN 60898 (domestic/commercial standard) and 15 kA per IEC 60947-2 (industrial standard) at DC. The IEC figure is the one to use when the prospective fault current exceeds 10 kA.

Will the 5SY5425-6 drop into a panel specified around the 5SY5232-6 without rewiring?

Both are 4-pole SENTRON 5SY5 breakers on the same DIN-rail footprint (72 mm wide, 4 width units), so the mechanical fit is identical. The difference is rating: 5SY5425-6 is 25 A B-curve; 5SY5232-6 is 32 A C-curve. If the circuit requires 25 A B-curve protection, the 5SY5425-6 is a direct swap — no rewiring needed.

MPN
5SY5425-6