Skip to main content
Siemens 5SY6602-7 — 4-Pole MCB (DIN Rail)

Siemens 5SY6602-7 SENTRON MCB, 4P C-Curve 2A, 30kA

MPN5SY6602-7
Active

Siemens SENTRON 5SY6602-7, 4-pole (3P+N) miniature circuit breaker, C-curve, 2 A rated, 30 kA breaking capacity per IEC 60947-2, 6 kA per EN 60898.

$33.02Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY6602-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6602-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC2 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Voltage typeAC
5SY6602-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 608986 kA
Rated breaking capacity, per IEC 60947-230 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY6602-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY6602-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C

Product details

The Siemens 5SY6602-7 is a 4-pole (3P+N) SENTRON miniature circuit breaker with a C-curve tripping characteristic, rated at 2 A at 35 °C on AC supply.

Ratings that matter for fit

The 6 kA per EN 60898 is the residential/commercial rating; the higher IEC 60947-2 rating is what matters for machinery panels. Temperature derating is built in: at 45 °C the continuous current drops to 1.85 A, at 50 °C to 1.8 A, at 55 °C to 1.75 A — if the panel runs hot, you need to account for that or step up one frame size.

Mounting position is any — horizontal, vertical, upside down — no derating required. Sealable, halogen-free, silicon-free — relevant for food, pharma, or clean-room panels where outgassing or tamper-proofing is specified.

Frequently asked questions

How do I get current pricing and availability for 5SY6602-7?

Submit an RFQ through this listing. Availability and current pricing are confirmed at quote time through independent distribution channels.

What is 5SY6602-7's listed depth on this component line?

Overall depth is 76 mm; installation depth (behind the panel face) is 70 mm.

What is 5SY6602-7's listed width on this component line?

Width is 72 mm, which corresponds to 4 modular width units on a standard DIN-rail profile.

Will 5SY6602-7 drop into a panel specified around 5SY6602-8 without rewiring?

The 5SY6602-8 is a different rating variant in the same SENTRON 5SY6 family. Both share the same 4-pole (3P+N) form factor, 72 mm width, and DIN-rail mounting — so mechanical fit is identical. The difference is the current rating and possibly the breaking capacity; verify the load current and fault level before substituting.

What compliance documentation does this brand provide for 5SY6602-7?

The SENTRON series carries IEC 60947-2 and EN 60898 certifications as standard. The breaker is halogen-free and silicon-free, which supports RoHS and clean-room compliance. Specific UL, CSA, or REACH declarations should be requested with the RFQ.

MPN
5SY6602-7