Siemens 5SY6625-6 — Miniature Circuit Breakers (MCB)

Siemens 5SY6625-6 SENTRON MCB, 4P B-Curve 25A, 6/15 kA

MPN5SY6625-6
Active

Siemens SENTRON 5SY6625-6, 4-pole (3P+N) miniature circuit breaker, B-curve, 25 A at 35 °C, 400 V AC, 6 kA (EN 60898) / 15 kA (IEC 60947-2).

$36.83Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

5SY6625-6 — Ratings
ParameterValue
Overvoltage categoryIII
5SY6625-6 — Mechanical
ParameterValue
Width72 mm
Height90 mm
Depth76 mm

Product details

The 5SY6625-6 is a Siemens SENTRON 4-pole miniature circuit breaker — 3P+N, B-curve, rated 25 A at 35 °C and 400 V AC. Breaking capacity sits at 6 kA per EN 60898 and 15 kA per IEC 60947-2 — the higher figure applies when the breaker is installed per the industrial standard, giving you a 15 kA SCCR at 400 V for fault interruption without upstream cascade. Current derates with ambient temperature: 25 A at 35 °C, 24 A at 40 °C, 23.5 A at 45 °C, 22.98 A at 50 °C, 22.45 A at 55 °C. If your panel runs hot, size the load to the derated value at the actual ambient — the 25 A nameplate is only good at 35 °C.

Installation depth is 70 mm; total depth including the front arc is 76 mm. Mounting position is any — vertical, horizontal, upside down in a tight enclosure — no derating needed for orientation. Sealable with a lead seal or adhesive label for tamper-proofing in metering or critical circuits.

Frequently asked questions

What is the breaking capacity of 5SY6625-6?

6 kA per EN 60898 and 15 kA per IEC 60947-2 at 400 V AC. The 15 kA figure applies when the breaker is installed per the industrial standard, giving higher fault-interrupt capability for panel coordination.

Will 5SY6625-6 drop into a panel specified around 5SY4140-7?

Both are 4-pole SENTRON MCBs on the same DIN-rail footprint (4 MW / 72 mm wide), so mechanical fit is the same. The difference is the trip curve — 5SY6625-6 is B-curve (3–5x In), while 5SY4140-7 is C-curve (5–10x In). If the panel was coordinated for C-curve selectivity, swapping to B-curve will trip faster on inrush and may lose discrimination with the upstream breaker.

How do I get current pricing and availability for 5SY6625-6?

Submit an RFQ through this listing. The part is sourced to order through independent distribution; availability and current pricing are confirmed at quote time — no stock count or price is published here.