Skip to main content
Siemens 5SY6632-6 — 4-Pole MCB (DIN Rail)

Siemens SENTRON 5SY6632-6 MCB, 32 A, 4-pole, B-curve

MPN5SY6632-6
Active

Siemens SENTRON miniature circuit breaker, 5SY6632-6, 4-pole (3P+N), 32 A, B-curve, 6 kA / 15 kA, IP20.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY6632-6 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY6632-6 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SY6632-6 — Protection
ParameterValue
Tripping characteristic (trip curve)B
Energy limitation class3
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY6632-6 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY6632-6 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY6632-6 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)2.6 W

Product details

It's built for final-subcircuit protection in commercial and industrial panels, switching the neutral conductor as well as the three phases. Dual-rated at 6 kA per IEC/EN 60898-1 and 15 kA per IEC 60947-2 / UL1077, so it covers both domestic-standard and industrial-breaking-capacity specs on the same device.

The 32 A rating holds at 35 °C ambient; at 40 °C it derates to 30.72 A, at 45 °C to 30.08 A, at 50 °C to 29.41 A, and at 55 °C to 28.74 A.

Mounting position is any — vertical, horizontal, upside down — which simplifies panel layout when space is tight. The combined terminal at top and bottom accepts both busbar and cable, and the unit is sealable for tamper-proof installations.

Frequently asked questions

What is the breaking capacity of 5SY6632-6?

It is dual-rated: 6 kA per IEC/EN 60898-1 and 15 kA per IEC 60947-2 / UL1077.

Will 5SY6632-6 drop into a panel designed for 5SY4140-7?

Yes — both are 4-pole SENTRON MCBs on the same DIN-rail footprint (4 modular-width units, 72 mm wide). The 5SY4140-7 is a 40 A C-curve; the 5SY6632-6 is a 32 A B-curve. No rewiring or panel modification needed.

Where can I buy 5SY6632-6?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
5SY6632-6