Siemens 5SY7614-7 — 4-Pole MCB (DIN Rail)

Siemens 5SY7614-7 SENTRON MCB, 4-pole C-curve 0.3 A, 15/50 k

MPN5SY7614-7
Active

Siemens SENTRON 5SY7614-7, miniature circuit breaker, 4-pole (3P+N), C-curve, 0.3 A rated current, 15 kA (EN 60898) / 50 kA (IEC 60947-2) breaking capacity, 400 V AC, width 72 mm (4 MW).

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY7614-7 — Identification
ParameterValue
Type / order code5SY7
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY7614-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC400 V
Rated current (In), AC0.3 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY7614-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 6089815 kA
Rated breaking capacity, per IEC 60947-250 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY7614-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY7614-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY7614-7 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

Integrator's note — 5SY7614-7

The Siemens 5SY7614-7 is a 4-pole (3P+N) miniature circuit breaker from the SENTRON 5SY7 series, rated at 0.3 A with a C-curve tripping characteristic. It breaks faults at 15 kA per EN 60898 and 50 kA per IEC 60947-2 at 400 V AC — the 50 kA figure is the industrial-grade interrupting capacity you rely on for high-fault panels.

Selectivity and coordination

Energy limiting class 3 means this MCB limits let-through energy tightly — essential for downstream coordination with smaller branch breakers or contactors. The 0.3 A C-curve is a niche rating: it protects lightly loaded control transformers, PLC power supplies, or signal-conditioner circuits where a standard 1 A or 2 A breaker would not trip fast enough on a low-impedance fault. Pair it with a 5SY6008-7 (1 A, same form factor) only if the load current is below 0.3 A; otherwise the 5SY6008-7 will not provide adequate overload protection.

Panel integration

The sealable cover allows lockout/tagout. Terminal capacity of 35 mm² solid or stranded covers large incoming feeds or busbar connections.

Frequently asked questions

What are the key ratings of the 5SY7614-7?

Rated current 0.3 A, C-curve, 4-pole (3P+N), 400 V AC, breaking capacity 15 kA per EN 60898 and 50 kA per IEC 60947-2. DC breaking capacity is 15 kA at 72 V DC maximum.

Will the 5SY7614-7 drop into a panel specified for 5SY6008-7?

Yes — same 72 mm width (4 MW), same DIN-rail mounting, same terminal range (0.75–35 mm²). The only functional difference is the rated current (0.3 A vs 1 A) and the tripping curve (both are C-curve). No rewiring needed if the load is ≤0.3 A.

How do I get current pricing and availability for the 5SY7614-7?

Sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.