Siemens 5SY7616-7CC — 4-Pole MCB (DIN Rail)

Siemens 5SY7616-7CC SENTRON MCB, 4P C-curve 16 A, 400 V

MPN5SY7616-7CC

Siemens SENTRON 5SY7616-7CC, miniature circuit breaker, 4-pole (3P+N), C-curve, 16 A rated current, 400 V AC, 25 kA IEC 60947-2 breaking capacity, 5 kA UL 1077, current production.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY7616-7CC — Identification
ParameterValue
Type / order code5SY7CC
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY7616-7CC — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC400 V
Rated current (In), AC16 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY7616-7CC — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity, per IEC 60947-225 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY7616-7CC — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY7616-7CC — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY7616-7CC — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens SENTRON 5SY7616-7CC is a 4-pole miniature circuit breaker (3P+N) with a C-curve tripping characteristic, rated 16 A at 400 V AC. It breaks up to 25 kA per IEC 60947-2 and 5 kA per UL 1077 / CSA C22.2 No. 235 — the IEC figure governs European panel coordination; the UL figure tells you it passes North American branch-circuit recognition for export builds or dual-rated machines.

At 25 kA (IEC 60947-2) this MCB sits in the high-breaking-capacity tier for a 16 A frame — enough for most secondary distribution boards with a transformer upstream. The 5 kA UL 1077 figure is a supplementary-protector rating, not a full branch-circuit rating per UL 489; if your BOM calls for a UL 489 listed breaker, this part won't satisfy that requirement. The 440 V multi-phase rating covers 3-phase line-to-line faults on a 400 V system with margin.

Occupies 4 width units (72 mm,) at 70 mm installation depth. Neutral conductor switching is integrated — no separate neutral link needed in the 3P+N configuration. IP20 with connected conductors; sealable for panel-lockout tagging. Mounting position any.

Environmental and service life

Rated for -40 °C to 75 °C ambient. Mechanical service life 10 000 switching cycles typical. Overvoltage category III suits fixed-installation distribution boards.

Frequently asked questions

What are the key ratings of the 5SY7616-7CC?

It is a 4-pole (3P+N) C-curve miniature circuit breaker rated 16 A at 400 V AC, with an IEC 60947-2 breaking capacity of 25 kA and a UL 1077 supplementary-protector rating of 5 kA. The multi-phase rating extends to 440 V AC.

Where can I buy the 5SY7616-7CC?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm commitment.

What compliance documentation is available for the 5SY7616-7CC?

The breaker carries IEC 60947-2 and UL 1077 / CSA C22.2 No. 235 ratings. It is halogen-free and silicon-free. Full RoHS, REACH, and manufacturer declarations are available with the order documentation.

MPN