Skip to main content
Siemens 5SY7615-7 — 4-Pole MCB (DIN Rail)

Siemens 5SY7615-7 SENTRON MCB, 4P, C-1.6A, 15/50kA

MPN5SY7615-7
Active

Siemens SENTRON 5SY7 series, 4-pole miniature circuit breaker (3P+N), C tripping characteristic, 1.6 A rated current, 400 V AC, breaking capacity 15 kA (EN 60898) / 50 kA (IEC 60947-2), IP20, sealable, halogen-free.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

5SY7615-7 — Identification
ParameterValue
Type / order code5SY7
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY7615-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated current (In), AC400 V
Rated current (In), AC1.6 A
Rated voltage, AC (multi-phase)440 V
Rated voltage, AC (single-phase)440 V
Rated voltage, DC (max.)72 V
Voltage typeAC
Rated frequency50/60 Hz
5SY7615-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Rated breaking capacity (Icn), per EN 6089815 kA
Rated breaking capacity, per IEC 60947-250 kA
Breaking capacity, AC (UL 1077 / CSA C22.2 No.235)5 kA
Overvoltage categoryIII
Degree of protection (IP)IP20, with connected conductors
Neutral conductor switchingYes
Touch protectionYes
5SY7615-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
SealableYes
5SY7615-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY7615-7 — Performance
ParameterValue
Mechanical service life (switching cycles, typ.)10 000

Product details

The Siemens SENTRON 5SY7615-7 is a 4-pole miniature circuit breaker (3P+N) with C-curve tripping characteristic, rated 1.6 A at 400 V AC. It is listed as current production (lifecycle stage: current) and is sourced to order. Breaking capacity is 15 kA per EN 60898 and 50 kA per IEC 60947-2 — the higher IEC figure means this breaker coordinates with downstream devices in an industrial panel where fault current can exceed 15 kA. Rated for overvoltage category III, so it's suited for fixed-installation distribution boards — not just final circuits. Ambient temperature range -40 to +70 °C covers unheated enclosures and hot panel interiors.

Width is 72 mm (4 width units), installation depth 70 mm. Mounting position any — no derating required for horizontal orientation. Quick-assembly system snaps onto standard DIN rail. Combined terminal top and bottom — feed from either direction, no special busbar position. Sealable for LOTO lockout; touch protection IP20 with conductors connected. Halogen-free and silicon-free construction matters in clean-room or food-bev environments where outgassing can contaminate product or corrode contacts.

Coordination and selectivity

The C-curve (5-10× In) is standard for motor starters and transformer primaries — not for lighting or resistive loads where B-curve would trip faster. DC rating: 72 V maximum, 15 kA per IEC 60947-2. If your DC bus runs above 72 V, this breaker is not the right choice — step up to the 5SY7 DC-rated variants or a UL 489 listed DC breaker.

Lifecycle stage is current.

MPN
5SY7615-7