Skip to main content
Siemens 5SY8616-7 — 4-Pole MCB (DIN Rail)

Siemens 5SY8616-7 SENTRON MCB, 4P C-Char, 30 kA IEC

MPN5SY8616-7
Active

Siemens SENTRON 5SY8616-7, 4-pole miniature circuit breaker, C characteristic, 30 kA IEC 60947-2, 5 kA UL 1077, 400 V AC, 72 mm wide.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

5SY8616-7 — Identification
ParameterValue
Brand nameSENTRON
Application suitabilityMechanical engineering / industry
5SY8616-7 — Ratings
ParameterValue
Number of poles4
Pole configuration3P+N
Rated voltage, AC (multi-phase)440 V
5SY8616-7 — Protection
ParameterValue
Tripping characteristic (trip curve)C
Overvoltage categoryIII
Pollution degree3
Degree of protection (IP)IP20, with connected conductors
5SY8616-7 — Mechanical
ParameterValue
Width in modular units4
Width72 mm
Height90 mm
Depth76 mm
Installation depth70 mm
Fastening / mounting methodQuick assembly system
Mounting positionany
Combined terminal, topYes
Combined terminal, bottomYes
Tightening torque, max.75 °C
Tightening torque, min.-40 °C
SealableYes
5SY8616-7 — Environmental
ParameterValue
Halogen-freeYes
Silicone-freeYes
Influence of ambient temperature (derating)max. 95% to 55°C, max. 55% to 70°C, max. 35% to 75°C
5SY8616-7 — Performance
ParameterValue
Power loss per pole, AC (hot state, at In)1.6 W

Product details

The Siemens SENTRON 5SY8616-7 is a 4-pole (3P+N) miniature circuit breaker with C-curve tripping characteristic, rated 30 kA breaking capacity per IEC 60947-2 and 5 kA per UL 1077. It switches the neutral conductor and accepts supply from either end — no orientation fuss during panel wiring.

That puts it in the high-fault category — suitable for industrial panels fed by transformers or distribution boards with high prospective short-circuit current. The 5 kA UL 1077 rating covers North American supplementary protection applications; the 15 kA DC rating at 60 V (max 72 V) handles DC control circuits or battery-backed loads.

C-curve and load selection

It's not for pure motor starting (use D-curve) nor for purely resistive heaters (B-curve would do). The 4-pole form with switched neutral is common in IT/TN-S systems where you want to isolate all conductors on a fault.

Vibration resistance per IEC 60068-2-6: ±1 mm at 5–25 Hz, 50 m/s² at 25–150 Hz.

Frequently asked questions

What is the breaking capacity of 5SY8616-7?

30 kA at 400 V AC per IEC 60947-2, 15 kA at 60 V DC per IEC 60947-2, and 5 kA per UL 1077 / CSA C22.2 No. 235.

Will 5SY8616-7 drop into a panel specified around 5SY4140-7 without rewiring?

Both are 4-pole SENTRON MCBs with the same 72 mm width and DIN-rail mount, so the mechanical fit is identical. The 5SY8616-7 carries a higher 30 kA IEC breaking capacity versus the 5SY4140-7's rating — verify the upstream fault level before swapping, but the footprint and terminal layout match.

What compliance documentation does Siemens provide for 5SY8616-7?

The MCB is certified to IEC / EN 60947-2 and UL 1077. It is halogen-free and silicon-free, which supports RoHS and REACH compliance declarations. Pollution degree 3 and overvoltage category III are rated per IEC standards.

Where can I buy 5SY8616-7 and how is it quoted?

Sourced through independent distribution channels and quoted to order against an RFQ. Availability and current pricing are confirmed at quote time — no stock count or price is published here.

MPN
5SY8616-7