Skip to main content
Delta VFD015E23A

Delta VFD015E23A AC Drive, 1.5 kW, 230 V 3-phase

MPN VFD015E23A

Delta VFD015E23A variable frequency drive, 1.5 kW / 2 HP, 230 V three-phase input, standard version, 1.9 Kg.

$310.00 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

VFD015E23A specifications
ParameterValue
Weight1.9 Kg

Product details

What sits in the panel

The Delta VFD015E23A is a variable-frequency drive sized for a 2 HP (1.5 kW) motor on a 230 V three-phase mains supply, with the model code itself spelling that out — the 015 segment marks the 1.5 kW rating and the 23 segment marks the three-phase 230 V class. It is the standard-drive variant of the VFD-E family, not a high-performance or application-specific build, which is what the A suffix in the order code is intended to flag for the panel builder reading the nameplate.

Sizing it against the motor it has to run

At 1.5 kW this is the right slot for small three-phase loads — fans, blowers, small pumps, conveyors, mixers — where the drive's three-phase 230 V input matches the motor winding and there is no need for a step-up transformer ahead of it. The form factor is shared with the wider VFD-E line, which means existing panel cutouts, gland plate entries and DIN-rail / panel-mount layouts built for this chassis do not have to be re-engineered when a unit is swapped out, provided the rating is held at or below the original spec.

When the cabinet was built around the 3.7 kW sibling

That shared footprint means VFD015E23A will physically drop into a slot originally specified for the 3.7 kW unit, but the motor output capability drops from 5 HP to 2 HP — the wiring and breaker upstream are not the constraint, the motor's torque demand is, so a substitution has to be confirmed against the driven load before the BOM line is closed.

Sourcing posture for this code

Lifecycle status is recorded as current on the manufacturer's product record, with no official successor or cross-reference flagged in the order-code breakdown — the standard version is still the active build being shipped against new orders.

MPN
VFD015E23A