Specifications

E5CC-QX2DBM-001 specifications
ParameterValue
SeriesE5CC
Output signalRelay (2), Voltage (External SSR)
Supply voltage24 VAC/DC
IP ratingIP66
MountingPanel Mount
Temp operating max55 °C
Temp operating min-10 °C
Weight0.265 lb (120.2 g)
PackageBox
Control methodOn/Off, Proportional (PID)

Product details

The Omron E5CC-QX2DBM-001 is a 1/16 DIN panel-mount process temperature controller accepting universal inputs — RTD (Pt100), thermocouple types B, E, J, K, L, N, PLII, R, S, T, U, W, plus 0–20 mA or 0–10 VDC linear signals — so it covers most industrial temperature sensing without needing a separate signal conditioner. Outputs are two relay contacts plus a voltage pulse for driving an external SSR, giving you a dedicated heater drive channel and a separate alarm or event output on the relays. Power it from 24 VAC or 24 VDC — common in control panels where a single 24 V supply feeds the PLC and panel instruments — and the spring-cage terminals accept 0.2–2.5 mm² solid or ferruled stranded without needing a screwdriver torque check.

What the IP66 rating means on a panel-mount controller

The IP66 front-panel seal means the controller withstands hose-down cleaning and condensation — suitable for food-processing, washdown, or outdoor enclosures where a standard IP20 front would let moisture into the display cavity. The square 45.00 mm x 45.00 mm panel cutout is the standard 1/16 DIN footprint; it drops into existing punch-outs without adapter plates.

Heater fault detection built in

The integrated heater fault detection monitors current draw on the load side and flags a broken heater or SSR short — a feature that normally requires an external current transformer and alarm module on simpler controllers. Control method is selectable between on/off and full PID with auto-tune, so you can commission it as a simple limit controller or let it self-tune for a closed-loop process.