Skip to main content
Omron G3PW-A220EC-C-FLK

Omron G3PW-A220EC-C-FLK Power Controller, 1~20A, RS-485

MPN G3PW-A220EC-C-FLK
Active

Omron G3PW series power controller, chassis mount, 100~240 VAC supply, 1~20 A input range, dual solid-state outputs, RS-485 CompoWay/F, spring terminals.

$264.54 – $705.38 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

G3PW-A220EC-C-FLK specifications
ParameterValue
SeriesG3PW
Output signalSolid State (2)
Display typeLED - Red Characters
Product typePower Controller
Supply voltage100 to 240VAC
ProtocolRS-485 (CompoWay/F)
MountingChassis Mount
Temp operating max55 °C
Temp operating min-15 °C
Weight2.3 lbs (1 kg)
PackageBox
Control methodOn/Off, Phase Control

Product details

The Omron G3PW-A220EC-C-FLK is a chassis-mount power controller from the G3PW series, designed to regulate current to resistive heater loads — common in packaging machinery, injection molding, and industrial ovens where precise thermal control is needed. It accepts a 100 ~ 240 VAC supply and handles a 1 ~ 20 A input range, with dual solid-state outputs switching via On/Off or phase-control methods.

The 1 ~ 20 A input range sets the load current the controller can regulate — sized for a single medium heater zone or a small multi-zone oven. The dual solid-state outputs mean it can drive two independent heater circuits or one circuit with redundant switching, common in safety-critical thermal applications. RS-485 communications using the CompoWay/F protocol allow the controller to be polled by a PLC or HMI for setpoint changes, readback of actual current, and heater fault status — useful on a packaging line where recipe changes happen between SKU changeovers. Heater fault detection monitors the load current and flags an alarm if the heater draws outside a programmed window — catches a failed SSR or open heater element before the line produces scrap. The event input lets an external PLC or safety relay reset the alarm or force a safe state. Chassis mount means it bolts to a backplate or sub-panel, not a DIN rail, so plan for screw-down clearance.

For a BOM line or a line-down replacement, the key fit criteria are the 1 ~ 20 A input range, 100 ~ 240 VAC supply, and RS-485 CompoWay/F communications. If your panel was specified around a different Omron power controller, verify the current range and communication protocol — the G3PW series uses a dedicated protocol, not Modbus.

MPN