Skip to main content
Omron H3Y-2-B AC100-120 5S

Omron H3Y-2-B AC100-120 5S Timer, DPDT, 0.2–5s

MPN H3Y-2-B AC100-120 5S
Active

Omron H3Y series plug-in time delay relay, DPDT mechanical, 0.2 sec to 5 sec delay, 5 A at 250 VAC contact, 100 to 120 VAC supply, socketable mount, H3Y-2-B AC100-120 5S.

$109.95 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

H3Y-2-B AC100-120 5S specifications
ParameterValue
SeriesH3Y
TypeMechanical Relay
Supply voltage100 to 120VAC
MountingSocket
PackageBulk
Delay time0.2 Sec to 5 Sec
Timing initiate methodInput Voltage
Timing adjustment methodHand Dial

Product details

What the H3Y timer does in the panel

The Omron H3Y-2-B AC100-120 5S sits in the control section of an industrial panel as a plug-in time delay element, where it holds a DPDT output (2 Form C) for an adjustable interval after the initiate signal arrives. Timing is set by a hand dial on the face of the unit across a 0.2 sec to 5 sec window, suited to short-cycle sequencing rather than hour-scale timing — cascade two units or step up to a longer-range H3Y variant if the process needs tens of seconds or minutes.

Contact rating and supply — fit envelope

The output is a mechanical relay rated 5 A at 250 VAC per the datasheet title line, which is the figure that decides whether the timer can drive a contactor coil, a solenoid, or an indicator lamp directly — anything heavier than 5 A at that voltage needs an interposing relay downstream. The DPDT contact set gives two independent Form C circuits, so the same timer can switch a load and a status feedback simultaneously. Supply is 100 to 120 VAC nominal, matching the common North American and Japanese control-transformer secondary; the 11-pole plug-in termination is what makes field replacement a socket pull rather than a rewire, which matters for service loops on installed machinery.

The product is recorded as Active by the manufacturer and the lifecycle stage on file is mature — a long-running series rather than a recent release. For procurement audit purposes the BOM line resolves to a single order code against an 11-pin socket; specifying it as H3Y-2-B AC100-120 5S with the explicit timing range (0.2 sec to 5 sec) and supply band (100 to 120 VAC) eliminates ambiguity between the on-delay and off-delay variants that share the same housing.

MPN
H3Y-2-B AC100-120 5S