ABB 3AUD0000000001 HVAC Packaged Drive, 75 Hp, 96 A, 440-480

MPN 3AUD0000000001
Active

ABB, ACH580 series, HVAC packaged drive with e-clipse bypass and circuit breaker disconnect, 3AUD0000000001, 440-480 V 3-phase, 75 Hp / 96 A UL light-overload, NEMA 3R enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3AUD0000000001 specifications
ParameterValue
Input voltage440 ... 480 V
Frequency50/60 Hz
Phases3-phase

Product details

HVAC packaged drive with e-clipse bypass

The ABB 3AUD0000000001 is an HVAC packaged drive combining an ACH580 variable-frequency drive with an e-clipse bypass and a circuit breaker disconnect in a single NEMA 3R enclosure. It's built for outdoor or weather-protected rooftop installation — the Type 3R rating means it sheds rain and resists ice formation, so no additional weather shield is needed for most commercial HVAC applications. Rated for 440 to 480 V three-phase input at 50/60 Hz, the drive delivers 75 Hp (96 A) under UL light-overload duty. That 96 A figure is the continuous output current for the light-overload profile — the rating that governs fan and pump loads where the drive runs at full load for extended periods, not just during acceleration.

The 75 Hp / 96 A UL light-overload rating is the spec that decides whether this drive handles the motor on your fan or pump. Light-overload (typically 110% for 60 seconds) is the HVAC standard profile — it matches the starting and running demands of centrifugal loads. If your application calls for heavy-overload (150% for 60 seconds, typical for conveyors or compressors), this drive's rating curve changes; verify the motor FLA against the heavy-overload current table for the ACH580 frame before specifying. The NEMA 3R enclosure means the drive is rated for outdoor installation without a secondary rain hood. It's not submersible (that would be NEMA 4X or 6), but it handles rain, sleet, and external ice formation common on roof-mounted HVAC units. The circuit breaker disconnect integrated into the package satisfies NEC local disconnect requirements, eliminating a separate external disconnect switch.

Integration notes

The e-clipse bypass allows the motor to run at full speed directly from line power if the drive is taken offline for service — a common requirement for critical HVAC loads like chiller pumps or hospital AHUs where airflow cannot stop. The bypass is built into the same enclosure, so no external bypass contactor or interlocking is needed. The circuit breaker disconnect provides a visible break for lockout/tagout compliance.