Skip to main content
ABB 3AUD0000004272

ABB 3AUD0000004272 HVAC Drive, 100 HP, 99 A, NEMA 3R

MPN 3AUD0000004272
Active

ABB 3AUD0000004272 HVAC packaged drive, ACH580-BCR-099A-6+B058, 500-600 V, 3-phase, 50/60 Hz, 100 Hp UL light-overload, 99 A, NEMA Type3R enclosure with e-clipse bypass and circuit breaker disconnect.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

3AUD0000004272 specifications
ParameterValue
Input voltage500 ... 600 V
Frequency50/60 Hz
Phases3-phase

Product details

The ABB 3AUD0000004272 is a UL-listed HVAC packaged drive combining an ACH580 variable-frequency drive with an e-clipse bypass and a circuit breaker disconnect in one NEMA Type3R enclosure. It's rated for 100 Hp light-overload use (99 A output) on 500-600 V three-phase mains, 50/60 Hz. The NEMA 3R enclosure means it's built for outdoor or unconditioned indoor installation — rain-tight and sleet-resistant, suitable for rooftop units or pad-mounted installations where a separate weather shelter isn't practical.

The 100 Hp / 99 A UL light-overload rating governs the motor it can drive continuously in a typical HVAC fan or pump application. Light-overload (110% for 60 s) is the standard duty cycle for variable-torque loads; if your application requires constant-torque or high starting torque (conveyor, positive-displacement pump), the drive must be oversized. The 500-600 V input range covers 480 V and 575 V nominal systems common in North American industrial and commercial HVAC. The NEMA 3R enclosure is rainproof but not dust-tight — it's correct for outdoor wall-mount or rooftop installations but not for washdown areas or dusty environments where NEMA 4/4X or 12 would be specified.

Integration notes

The e-clipse bypass allows the motor to run at line frequency when the drive is taken offline for service — a common requirement for critical HVAC loads where a failed drive can't stop the fan or pump. The circuit breaker disconnect provides integral branch-circuit protection, eliminating the need for a separate disconnect switch upstream. The NEMA 3R enclosure has conduit knockouts on the bottom; gland plates and wiring must maintain the rainproof seal.

MPN
3AUD0000004272